No, interior or exterior stairs that are not part of a required means of egress do not have to meet the Standards.
Search Results "Exit Stairway"
Commonly Searched Documents
-
Are stairs that are not part of means of egress required to comply with the Standards?
-
11B-504.4.1 Contrasting stripe
Interior stairs shall have the upper approach and lower tread marked by a stripe providing clear visual contrast. Exterior stairs shall have the upper approach and all treads marked...
-
11B-504.4.1 Contrasting stripe
Interior stairs shall have the upper approach and lower tread marked by a stripe providing clear visual contrast. Exterior stairs shall have the upper approach and all treads marked...
-
Are doors or gates to employee work areas required to comply?
Areas used only by employees as work areas must provide access for approach, entry, and exit, including means of egress....
-
Avoid the extremes of surface reflectivity and contrast (slides 11 and 13)
Stairways This one [slide 12 photo], I actually have a question for the low-vision users in the room. We’ve got a picture of a stair. It’s got stair texture to it....
-
207 Accessible Means of Egress
207 Accessible Means of Egress
-
1132A.4, Item 1
., concrete, brick, flagstone) serving primary entry doors and required exit doors are limited to not more than ½ inch (12.7 mm) of change in height between floor surfaces....
-
1132A.4, Item 1
., concrete, brick, flagstone) serving primary entry doors and required exit doors are limited to not more than ½ inch (12.7 mm) of change in height between floor surfaces....
-
1007.4 Elevators
The elevator shall be accessed from either an area of refuge complying with Section 1007.6 or a horizontal exit....
-
3. Are ramps, transfer systems, and stairs permitted to be counted as play components?
3. Are ramps, transfer systems, and stairs permitted to be counted as play components? No. The Standards do not permit steps, ramps, transfer systems, decks, or roofs to be...
-
Alterations to stairs (Section-by-Section Analysis)
Alterations to stairs. The 1991 Standards only require interior and exterior stairs to be accessible when they provide access to levels that are not connected by an elevator, ramp,...
-
Handrail Extensions [§505.10]
Handrail Extensions [§505.10] Handrail extensions at the top and bottom must return to walls, guards, or floors and horizontal portions must comply as protruding objects. The...
-
Alterations to stairs. (Section-by-Section Analysis)
Alterations to stairs. The 1991 Standards only require interior and exterior stairs to be accessible when they provide access to levels that are not connected by an elevator, ramp,...
-
A. Signs
__ No __ N/A __ Comments: ___________________________________________ Mechanical and electrical rooms Yes __ No __ N/A __ Comments: ___________________________________________ Stairways...
-
Do requirements of accessible means of egress apply to employee work areas?
The ADA Standards (§203.9) require that employee work areas “be designed and constructed so that individuals with disabilities can approach, enter, and exit the employee work area” and apply...
-
1009.1 Accessible means of egress required
Accessible means of egress shall comply with this section. Accessible spaces shall be provided with not less than one accessible means of egress. Where more than one means of egress...
-
210 Stairways
1991 Standards for Accessible Design 2010 Standards for Accessible Design What’s New/Different 4.1.3(4)...
-
11B-809.8.3 Door maneuvering clearance.
At the dwelling unit side of the primary entry doors, secondary exterior doors, and required exit doors maneuvering clearances shall be 44 inches (1118 mm) minimum in length measured...
-
9.5.2(2)(a)
(a) at least one public entrance shall allow a person with mobility impairments to approach, enter and exit including a minimum clear door width of 32 in (815 mm)....
-
Tactile Signage
., room and exit labels) because doorways provide a tactile cue in locating signs....
-
1009.7 Exterior areas for assisted rescue
Where the exit discharge does not include an accessible route from an exit located on the level of exit discharge to a public way, an exterior area of assisted rescue shall be provided on...
-
1009.7 Exterior areas for assisted rescue
Where the exit discharge does not include an accessible route from an exit located on the level of exit discharge to a public way, an exterior area of assisted rescue shall be provided on...
-
11B-809.8 Doors
Primary entry doors, required exit doors, secondary exterior doors and interior doors intended for user passage shall comply with this section and Section 11B-404.2....
-
11B-705.1.2.2 Curb ramps
Detectable warnings at curb ramps shall comply with Section 11B-705.1.2.2.