Specifications for raised characters in section 703.2 address the depth, case, style or font type, character proportion and height, stroke thickness, and character and line spacing....
Search Results "Closer Height"
Commonly Searched Documents
-
Raised Characters
-
Architect
The 4040XP provides adjustments for Position 1-6, has a range of interior and exterior door sizes it can work on. It also has a top jamb mounted configuration that can maintain the...
-
Transfer Protocols
Summary description and experimental setup for the five protocols (A-E) Protocol A: Adjustable Height Level height, maximum height transfer and minimum height...
-
A4.32.4 Height of Tables or Counters
A4.32.4 Height of Tables or Counters. Different types of work require different table or counter heights for comfort and optimal performance....
- Figure 904.3.2 Check-Out Aisle Counters – Drawing from the U.S. Access Board
-
11B-411.2.1.2.4.2 Size
Elevator assignment characters shall be 1 inch high (25 mm) minimum.
-
19 Inch Low Height
Figure 2: Illustration of the height difference between a fixed height and adjustable height medical table Implications of a 19 Inch Minimum Standard for the Highest Point in the Lowest...
-
A4.32.4 HEIGHT OF WORK SURFACES
Heavy manual work such as rolling dough requires a work surface height about 10 in (255 mm) below elbow height for a standing person....
-
a. Transfer Surface Adjustability
The Board considered it likely that diagnostic equipment would be adjustable in height to serve practitioners’ needs however, the transfer surface could be fixed within the proposed height...
-
18 Inch Low Height
18 Inch Low Height As our discussions progressed on the low height, whether it should be 17 inches, 18 inches or 19 inches; a compromise position of 18 inches was suggested....
-
11B-604.4 Seats
The seat height of a water closet above the finish floor shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum measured to the top of the seat....
- Corbin Russwin Inc. DC3000 Series Cast Iron Door Closer
-
Line Spacing: ADA Standard Section 703.2.8
Spacing between the baselines of separate lines of raised characters within a message shall be 135 percent minimum and 170 percent maximum of the raised character height....
-
11B-703.2.8 Line spacing
Spacing between the baselines of separate lines of raised characters within a message shall be 135 percent minimum and 170 percent maximum of the raised character height....
-
17 Inch Low Height
17 Inch Low Height A portion of the Committee maintained that a height range of 17 inches - 25 inches would accommodate a significant portion of people with disabilities....
-
5.1.5 Floor Height
Where the floor at the entrance to the camp shelter is elevated above the ground surface, the floor shall be 17 (430 mm) high minimum to 19 inches (485 mm) high maximum measured from...
-
4.19.2 Height and Clearances
Lavatories shall be mounted with the rim or counter surface no higher than 34 in (865 mm) above the finish floor. Provide a clearance of at least 29 in (735 mm) above the finish...
-
4.19.2 HEIGHT AND CLEARANCES
Lavatories shall be mounted with the rim or counter surface no higher than 34 in (865 mm) above the finished floor. Provide a clearance of at least 29 in (735 mm) from the floor to...
-
602.4 Spout Height
602.4 Spout Height. Spout outlets shall be 36 inches (915 mm) maximum above the finish floor or ground....
-
11B-902.4.2 Height
The tops of tables and counters shall be 26 inches (660 mm) minimum and 30 inches (762 mm) maximum above the finish floor or ground.
-
11B-902.4.2 Height
The tops of tables and counters shall be 26 inches (660 mm) minimum and 30 inches (762 mm) maximum above the finish floor or ground.
-
11B-902.4.2 Height
The tops of tables and counters shall be 26 inches (660 mm) minimum and 30 inches (762 mm) maximum above the finish floor or ground.
-
505.4 Height
505.4 Height....
-
505.4 Height
Handrails shall be at a consistent height above walking surfaces, stair nosings, and ramp surfaces. Advisory 505.4 Height....