The area of rescue assistance shall not encroach on any required exit width....
Search Results "Ramp Width"
Commonly Searched Documents
-
4.3.11.2 Size
-
1017.5 Tread Obstacles
Where possible, tread obstacles that cross the full width of the trail tread should be separated by a distance of 48 inches (1220 mm) minimum....
-
1132A.9 Smooth surface
Swinging door or gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
11B-608.2.2 Standard roll-in type shower compartments
shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides with a full opening width...
-
1132A.9 Smooth surface
Swinging door or gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
Location: ADA Standard Section 206.3
Section 206.3 covers scoping requirements in the most current ADA Standards for the required locations of accessible routes.
-
Elevated Play Components: ADA Standard Section 240.2.2
Section 240.2.2 covers scoping requirements in the current ADA Standards for elevated play components.
-
11B-206.2.6 Performance areas
Performance areas, including but not limited to, stages, platforms and orchestra pits, are treated as raised or lowered areas within a given story and all are required to be accessible by ramp...
- Living Earth Crafts Essex™ Pedicure Chair
- Sargent HC 8800 Rim Exit Device
-
Keep Good Notes
If there isn’t an accessible entrance you’ll want to indicate how many steps there are and how much space is available to install a ramp or lift....
-
808.3 Clear Floor Space
alterations, wheelchair spaces are not required to be located within the defined area of raised jury boxes or witness stands and shall be permitted to be located outside these spaces where ramp...
-
4.6.5 PASSENGER LOADING ZONES
If there are curbs between the access aisle and the vehicle pull-up space, then a curb ramp complying with 4.7 shall be provided....
-
Are public accommodations required to retrofit existing buildings by adding elevators?
A public accommodation generally would not be required to remove a barrier to physical access posed by a flight of steps, if removal would require extensive ramping or an elevator....
-
1130A.1 General
For the purpose of this section, “accessible routes” may include hallways, corridors and ramps....
-
1130A.1 General
For the purpose of this section, “accessible routes” may include hallways, corridors and ramps....
- American Safety Tread Co., Inc. Type G500R Stairway Nosing Replacement
- American Safety Tread Co., Inc. Type SG4702 Stairway Nosing Replacement
- Takeform Fusion Signage Overheads Type C
- American Safety Tread Co., Type G505R Stairway Nosing/Tread Replacement
-
Medical Device Manufacturers
Board is considering: • Questions 9 and 10 on the technical criteria in Chapter M3; • Questions 14 (a) and (b) on height adjustable patient support surfaces; • Question 15 (b) on width...
- GE® 30" Free-Standing Electric Range JB450RFSS
-
1130A.1 General
For the purpose of this section, “accessible routes” may include hallways, corridors and ramps....
-
382.95 What are carriers’ general obligations with respect to boarding and deplaning assistance?
At U.S. airports with 10,000 or more annual enplanements, boarding assistance must be provided through the use of lifts or ramps, where level-entry boarding is not otherwise available (paragraph...