‘‘Accessible seating'' is defined in § 35.138(a)(1) of the final rule to mean ‘‘wheelchair spaces and companion seats that comply with sections 221 and 802 of the 2010 Standards along with...
Search Results "Clear Floor Space"
Commonly Searched Documents
-
Ticket sales. (Section-by-Section Analysis)
-
Van-Accessible Parking Spaces
Van-accessible parking spaces are the same as accessible parking spaces for cars except for three features needed for vans: a wider access aisle (96") to accommodate a wheelchair...
-
Doors: ADA Standard Section 604.8.1.2
Section 604.8.1.2 covers the current ADA Standards for wheelchair accessible compartment doors.
-
General: ADA Standard Section 307.1
Section 307.1 of the ADA Standards covers information in the current ADA Standards for protruding objects.
-
Protruding Objects: ADA Standard Section 204
Section 204 covers the scoping requirements of general exceptions for protruding objects in the most current ADA Standards
-
Protruding Objects: ADA Standard Section 307
Section 307 covers the current ADA Standards for protruding objects.
-
Transient Lodging Facilities: ADA Standard Section 206.5.3
Section 206.5.3 covers scoping requirements in the most current ADA Standards for accessible routes to transient lodging facilities.
-
11B-204 Protruding objects
[See subsections ...]
-
11B-307.1 General
Protruding objects shall comply with Section 11B-307.
-
11B-307 Protruding objects
[See subsections ...]
-
11B-406.5.1 Location
Curb ramps and the flared sides of curb ramps shall be located so that they do not project into vehicular traffic lanes, parking spaces, or parking access aisles....
-
Building Entrance
At least one door at the accessible entrance must have a minimum clear width of 32 inches for a voter who uses a wheelchair or other mobility device to pass through the doorway....
-
606.2 Sink Clear Floor Space
Is forward approach to sinks located in common use employee break rooms consisting of micorwaves, toaster, and refrigerator required?
-
Entrances
All door openings must provide a minimum width of 32 inches and there must also be enough room for a person using a wheelchair to maneuver to open the door, including 18 inches of clear...
-
Site, Building, or Floor Entrance: ADA Standard Section 809.5.6
Where a system, including a closed-circuit system, permitting voice communication between a visitor and the occupant of the residential dwelling unit is provided, the system shall...
-
Slope: ADA Standard Section 405.2
Section 405.2 covers the current ADA Standards for slope requirements on ramps.
-
11B-812.5 Accessible routes
[See subsections ...]
-
11B-812.8 Identification signs
EVCS identification signs shall be provided in compliance with Section 11B-812.8.
- Irwin Seating Company ADA Movable Base
-
Roll-in Access [1014.2.2]
When roll-in access is provided, a turning space at least 60 inches in diameter or a T-shaped space with an arm at least 60 by 36 inches and a base at least 36 inches wide and 24 inches...
-
Turnstiles and Security Gates at Entrances
Turnstiles and Security Gates at Entrances Businesses with narrow revolving turnstiles located at the entrance exclude people with disabilities unless accessible gates or passages...
-
T502.3 Doorways with Level Boarding
Doorways on non-rail vehicles designed for level boarding bus systems shall comply with T502.3.
-
9.2.2(3)
(3) Doors and doorways designed to allow passage into and within all sleeping rooms, suites or other covered units shall comply with 4.13.
-
9.4 Other Sleeping Rooms and Suites
Doors and doorways designed to allow passage into and within all sleeping units or other covered units shall comply with 4.13.5.