Firmness and Stability In addition to the visual inspection and calculation of the surface deficiency score, the firmness and stability of the surfaces were measured at each of the nine locations...
Search Results "Signage Location"
Commonly Searched Documents
-
Performance for Surface Firmness and Stability
-
606.2 Sink Clear Floor Space
Is forward approach to sinks located in common use employee break rooms consisting of micorwaves, toaster, and refrigerator required?...
- Viking E-1600A-BLT-EWP Emergency Tower Phone with Blue LED Beacon and Strobe Light
- Viking E-1600-IP VoIP Emergency Phones with Built-in Auto Dialer and Digital Announcer
- Viking E-1600-45A-EWP Emergency Phones with Built-in Auto Dialer and Digital Announcer with Weather Protection
-
Accessible Fishing Piers and Platforms
percent (25%) of railings, guards, or handrails (if provided) to be at a 34-inch maximum height (so that a person seated in a wheelchair can cast a fishing line over the railing) and to be located...
-
Access Aisle
Section 502.3 of the 2010 Standards provides the flexibility necessary to permit designers and others to determine the most appropriate location of the accessible route to the accessible...
-
1136A.2 Switch and control heights
or switches intended to be used by the occupant of the room or area to control lighting and receptacle outlets, appliances, alarms or cooling, heating and ventilating equipment shall be located...
-
11B-221.2.3.2 Vertical dispersion
In addition, wheelchair spaces shall be located in each balcony or mezzanine that is located on an accessible route. Exceptions: 1. ...
-
206.2.8 Employee Work Areas
Common use circulation paths located within employee work areas that are less than 1000 square feet (93 m²) and defined by permanently installed partitions, counters, casework, or furnishings...
-
Prevention of Fraud in Purchase of Tickets for Accessible Seating
stating that, if the user of the ticket does not need the specific features of the accessible seat, the venue may require the ticket holder to move to a different, non-accessible seating location...
-
206.2.8 Employee Work Areas
Common use circulation paths located within employee work areas that are less than 1000 square feet (93 m2) and defined by permanently installed partitions, counters, casework, or furnishings...
-
Emergency Egress
Emergency Egress ADAAG requires that accessible seating be located on an accessible route which also serves as a means of egress....
-
11B-221.2.3.2 Vertical dispersion
In addition, wheelchair spaces shall be located in each balcony or mezzanine that is located on an accessible route. [2010 ADAS] Advisory 221.2.3.2 Vertical Dispersion. ...
-
1136A.2 Switch and control heights
or switches intended to be used by the occupant of the room or area to control lighting and receptacle outlets, appliances, alarms or cooling, heating and ventilating equipment shall be located...
-
11B-221.2.3.2 Vertical dispersion
In addition, wheelchair spaces shall be located in each balcony or mezzanine that is located on an accessible route. Advisory 11B-221.2.3.2 Vertical dispersion....
-
1136A.2 Switch and control heights
or switches intended to be used by the occupant of the room or area to control lighting and receptacle outlets, appliances, alarms or cooling, heating and ventilating equipment shall be located...
-
Protrusion Limits: ADA Standard Section 307.2
Section 307.2 covers the current ADA Standards for protrusion limits.
-
General: ADA Standard Section 308.1
Section 308.1: of the ADA Standards covers information in the current ADA Standards for reach ranges.
-
Designated Aisle Seats: ADA Standard Section 221.4
Section 221.4 covers scoping requirements in the current ADA Standards for designated aisle seats in assembly areas.
-
Amusement Ride Seats Designed for Transfer: ADA Standard Section 1002.5
Where possible, designers are encouraged to locate the ride seat no higher than 17 to 19 inches (430 to 485 mm) above the load and unload surface....
-
Overlap: ADA Standard Section 604.3.2
Section 604.3.2 covers the current ADA Standards for overlapping clearances in the water closet clear floor space.
-
Dispensers: ADA Standard Section 604.7
Section 604.7 covers the current ADA Standards for toilet paper dispensers.
-
11B-307.2 Protrusion limits
Elements located on circulation paths, including operable elements, must comply with requirements for protruding objects....