When the only elevators provided for use by the public and employees are combination passenger and freight elevators, they shall comply with Section 11B-407 and with ASME A17.1....
Search Results "Shall"
-
11B-407.1.1 Combined passenger and freight elevators
-
11B-407.4.7.1.5 Button spacing
A minimum clear space of 3/8 inch (9.5 mm) or other suitable means of separation shall be provided between rows of control buttons....
-
11B-705.1.2.6 Reflecting pools
When detectable warnings are provided at reflecting pools, it shall be 24 inches (610 mm) minimum and 36 inches (914 mm) maximum in width....
-
Mirrors: ADA Standard Section 603.3
Section 603.3 covers the current ADA Standards for mirrors in toilet and bathing rooms.
-
Amusement Rides: ADA Standard Section 216.12
Section 216.12 covers scoping requirements in the current ADA Standards for signs at amusement rides.
-
Security Glazing: ADA Standard Section 904.6
Where counters or teller windows have security glazing to separate personnel from the public, a method to facilitate voice communication shall be provided....
-
Floor or Ground Surfaces: ADA Standard Section 304.2
Section 304.2 covers the current ADA Standards for the ground surfaces of a turning space.
-
11B-707.1 General
Automatic teller machines, fare machines and point-of-sale devices shall comply with Section 11B-707. [2010 ADA Standards] 707.1 General....
-
11B-206.7.6 Guest rooms and residential dwelling units
Platform lifts shall be permitted to connect levels within transient lodging guest rooms required to provide mobility features complying with Section 11B-806.2 or residential dwelling units...
-
11B-705.1.1.1 Dome size
Truncated domes in a detectable warning surface shall have a base diameter of 0.9 inch (22.9 mm) minimum and 0.92 inch (23.4 mm) maximum, a top diameter of 0.45 inch (11.4 mm) minimum and...
-
907.5.2.3.4 Groups R-2.1, R-3.1 and R-4
Protective social care facilities which house persons who are hearing impaired, shall be provided with notification appliances for the hearing impaired installed in accordance with NFPA...
-
11B-209.3 Medical care and long-term care facilities
At least one passenger drop-off and loading zone complying with Section 11B-503 shall be provided at an accessible entrance to licensed medical care and licensed long-term care facilities...
-
11B-302.3 Openings
Openings in floor or ground surfaces shall not allow passage of a sphere more than ½ inch (12.7 mm) diameter except as allowed in Sections 11B-407.4.3, 11B-409.4.3, 11B-410.4, 11B-810.5.3...
-
11B-603.3 Mirrors
Mirrors located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 40 inches (1016 mm) maximum above the finish floor or ground....
-
11B-206.4.3 Entrances from tunnels or elevated walkways
direct access is provided for pedestrians from a pedestrian tunnel or elevated walkway to a building or facility, all entrances to the building or facility from each tunnel or walkway shall...
-
11B-707.1 General
Automatic teller machines, fare machines and point-of-sale devices shall comply with Section 11B-707. [2010 ADA Standards] 707.1 General....
-
11B-603.3 Mirrors
Mirrors located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 40 inches (1016 mm) maximum above the finish floor or ground....
-
11B-302.3 Openings
Openings in floor or ground surfaces shall not allow passage of a sphere more than ½ inch (12.7 mm) diameter except as allowed in Sections 11B-407.4.3, 11B-409.4.3, 11B-410.4, 11B-810.5.3...
-
11B-209.3 Medical care and long-term care facilities
At least one passenger drop-off and loading zone complying with Section 11B-503 shall be provided at an accessible entrance to licensed medical care and licensed long-term care facilities...
-
11B-705.1.1.1 Dome size
Truncated domes in a detectable warning surface shall have a base diameter of 0.9 inch (22.9 mm) minimum and 0.92 inch (23.4 mm) maximum, a top diameter of 0.45 inch (11.4 mm) minimum and...
-
11B-206.7.6 Guest rooms and residential dwelling units
Platform lifts shall be permitted to connect levels within transient lodging guest rooms required to provide mobility features complying with Section 11B-806.2 or residential dwelling units...
-
907.5.2.3.4 Groups R-2.1, R-3.1 and R-4
Protective social care facilities which house persons who are hearing impaired, shall be provided with notification appliances for the hearing impaired installed in accordance with NFPA...
-
11B-206.4.3 Entrances from tunnels or elevated walkways
direct access is provided for pedestrians from a pedestrian tunnel or elevated walkway to a building or facility, all entrances to the building or facility from each tunnel or walkway shall...
-
General: ADA Standard Section 410.1
Section 410.1 of the ADA Standards covers information in the current ADA Standards for platform lifts.