A clear floor space complying with Section 11B-305 positioned for forward approach shall be provided....
Search Results "Seating Space"
Commonly Searched Documents
-
11B-902.4.1 Clear floor or ground space
-
J1
If the drinking fountain is a wall-mounted unit, is there clear floor space at least 30 inches wide (36 inches if it is in an alcove) x 48 inches long in front of the drinking fountain and...
-
11B-904.4.1 Parallel approach
A clear floor or ground space complying with Section 11B-305 shall be positioned for a parallel approach adjacent to the 36 inch (914 mm) minimum length of counter....
-
F202.6.2 Accessible Route
Elements and spaces required to be accessible by F202.6 shall be on an accessible route complying with F206....
-
M302.2.1 Adjustability (Section-by-Section Analysis)
The MDE NPRM proposed a transfer surface height range for diagnostic equipment used by patients in a seated position of 17 inches minimum and 19 inches maximum....
-
Looking at Cal Green 5.106.5.3, we must provide the conduits and panel capacity for future installation for the required number of spaces (2 in this case). However, it is only when the equipment is to be installed that we need to refer to CBC and CEC. Section 11B-228.3.1 also reiterates this. Therefore, we would show the location of the conduit stub outs adjacent to 2 current parking spaces and would show space on the electric panel for the future equipment – and that is all. At this time, we do not need to show the requirements for EV accessibility when equipment is installed per Chapter 11B. Is my interpretation correct?
RESPONSE: CBC Chapter 11B accessibility provisions for EVCS apply when a project consists of one or more electric vehicle charging spaces served by an electric vehicle charger or other charging...
-
10.3.1(19)
(19) Where provided, baggage check-in and retrieval systems shall be on an accessible route complying with 4.3, and shall have space immediately adjacent complying with 4.2....
-
11B-812.7.2 Marking
Access aisles at vehicle spaces shall be marked with a painted borderline around their perimeter....
-
Resting Intervals [1017.8]
A turning space that complies with section 304.3.2 of the ABA Standards must be provided....
-
Other Services and Accommodations
Where level-entry boarding is not available, there must be ramps or mechanical lifts to service most aircraft with 19 or more seats at U.S. airports with over 10,000 annual enplanements...
-
§ 38.179(b)
In addition, each such unit shall comply with §38.23 (b) or (c) and shall provide at least one space for wheelchair or mobility aid users complying with §38.23(d) of this part unless the...
-
5.4.4 Transfer Support Distance From Transfer Surface for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.4 Transfer Support Distance From Transfer Surface for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
-
1012.5 Slope
The slope of the surface of parking spaces and pull-up spaces shall not be steeper than 1:48 in any direction....
-
Gaps
Gaps Where wheelchair spaces are provided on amusement rides, the floors of rides must be coordinated with the floors of the load and unload areas so that when the ride is at the...
-
904.4.1 Parallel Approach
A clear floor or ground space complying with 305 shall be positioned for a parallel approach adjacent to the 36 inch (915 mm) minimum length of counter....
-
2) Where the Standard says "Changes in level are not permitted"
2) Where the Standard says "Changes in level are not permitted", such as 304.2 for turning spaces: Here the standard is followed by an unenforceable advisory that says, "As used in this...
-
904.4.1 Parallel Approach
A clear floor or ground space complying with 305 shall be positioned for a parallel approach adjacent to the 36 inch (915 mm) minimum length of counter....
-
904.4.1 Parallel Approach
A clear floor or ground space complying with 305 shall be positioned for a parallel approach adjacent to the 36 inch (915 mm) minimum length of counter....
-
T215.1 General
Communication features on non-rail vehicles shall comply with T215.
-
T215 Communication Features
[See subsections ...]
- Brewer Assist Power Procedure Table™
- American Standard Acrylic Shroud for American Standard Selectronic Faucets
- Access Board: Turning Space Size
-
Location: ADA Standard Section 703.4.2
Where there is no wall space at the latch side of a single door or at the right side of double doors, signs shall be located on the nearest adjacent wall....