11B-407.2.1.1 Height
[2010 ADA Standards] EXCEPTION: Existing call buttons and existing keypads shall be permitted to be located at 54 inches (1370 mm) maximum above the finish floor, measured to the centerline...
-
11B-407.2.2.1 Visible and audible signals
[2010 ADA Standards] 2. In existing elevators, a signal indicating the direction of car travel shall not be required....
-
11B-407.4.6.2.1 Size and shape
[2010 ADA Standards] 407.4.6.2.1 Size. Buttons shall be ¾ inch (19 mm) minimum in their smallest dimension....
-
Safe Harbor
Facilities|_ Compliance Dates and Applicable Standards for Barrier Removal and Safe Harbor Date Requirement Applicable Standards...
-
Accessible Parking Spaces
business or State or local government restripes parking spaces in a parking lot or parking structure (parking facilities), it must provide accessible parking spaces as required by the 2010 ADA...
-
11B-202.4 Path of travel requirements in alterations, additions and structural repairs
Standards] 202.4 Alterations Affecting Primary Function Areas....
-
11B-202.4 Path of travel requirements in alterations, additions and structural repairs
Standards] 202.4 Alterations Affecting Primary Function Areas....
-
Safe Harbors
, as follows (yellow highlights added by ETA; green text indicates 2010 ADAS): [ADA Title III] Appendix to §36.304(d) _|for Public Accommodations and Commercial Facilities; similar for...
-
"Existing Facility" (Section-by-Section Analysis)
Under the ADA, a facility is initially classified as one of three types: (1) An existing facility; (2) an altered facility; or (3) a newly designed and constructed facility. ...
-
ABBREVIATIONS
ABBREVIATIONS ABA Architectural Barriers Act of 1968 ADA Americans with Disabilities Act of 1990 ADAAG ADA Accessibility Guidelines for Buildings and Facilities - Appendix...
-
11B-405.5 Clear width
[2010 ADA Standards] 405.5 Clear Width. The clear width of a ramp run and, where handrails are provided, the clear width between handrails shall be 36 inches (915 mm) minimum....
-
11B-405.2 Slope
[2010 ADA Standards] EXCEPTION: In existing sites, buildings, and facilities, ramps shall be permitted to have running slopes steeper than 1:12 complying with Table 405.2 where such...
-
11B-607.4 Grab bars
[2010 ADA Standards] 607.4 Grab Bars. Grab bars for bathtubs shall comply with 609 and shall be provided in accordance with 607.4.1 or 607.4.2. Exceptions: 1. Reserved....
-
206.2.5 Restaurants and Cafeterias
Florida requirements may be waived down to the ADA Standards requirements....
-
C. REMEDIAL ACTION
, including the ADA Standards. 18....
-
Homeless Shelters, Group Homes, and Similar Social Service Establishments
Section 233 of the 2010 Standards includes specific scoping and technical provisions that apply to new construction and alteration of residential facilities....
-
3.3 Data Sources
3.3 Data Sources As noted above, MDE Advisory Committee utilized their own expertise in deliberations about accessibility standard specifications....
-
11B-1008.2.6 Ground surfaces
[2010 ADAS] Advisory 1008.2.6 Ground Surfaces. Ground surfaces must be inspected and maintained regularly to ensure continued compliance with the ASTM F 1951 standard....
-
Accessible Route
- Source: Definition from The ADA Standards at § 3.5....
-
16. Modification to be completed within six months
following physical, operational, and other modifications necessary to bring the Hotel, and its goods, services, facilities, privileges, advantages, and accommodations into compliance with the ADA...
-
f-v
[ADA Standards § 4.8.4] Yes No Note: if the running slope is less than 1:16 but more than 1:20, each ramp segment may be up to 40 feet long followed by a level landing]....
-
B4
[ADA Standards § 4.6.5] Yes No If No: Can the route be cleared by removing or raising low objects, or can each van accessible parking space be relocated?...