Water closet seats shall be 15 inches (381 mm) minimum and 19 inches (483 mm) maximum measured to the top of the seat above the finish floor.
Search Results "United States Access Board"
-
11B-809.10.7.4 Seat height
-
11B-809.10.8.4 Knee and toe clearance
Knee and toe clearance shall be provided and comply with Section 11B-306.
-
11B-809.10.7.2 Location
Water closets shall be located within bathrooms in a manner that permits a grab bar to be installed on at least one side of the fixture. The centerline of the water closet shall be...
-
11B-809.10.8.5 Plumbing protection
Plumbing protection shall comply with Section 11B-809.9.7.
-
11B-809.8.1 Door Thresholds
Primary entry doors, required exit doors, and interior doors intended for user passage shall have thresholds complying with Section 11B-404.2.5. Secondary exterior door thresholds,...
-
11B-809.10.8.5 Plumbing protection
Plumbing protection shall comply with Section 11B-809.9.7.
-
11B-809.10.7.3 Reinforcement for grab bars
Reinforcement for grabs bars shall comply with the following: Where water closets are not placed adjacent to a side wall capable of accommodating a grab bar, the bathroom...
-
11B-809.10.7.2 Location
Water closets shall be located within bathrooms in a manner that permits a grab bar to be installed on at least one side of the fixture. The centerline of the water closet shall be...
-
11B-809.10.8.1 Location
Lavatories without base cabinets shall be installed with the centerline 18 inches (457 mm) minimum from an adjoining wall or fixture to allow for forward approach. Lavatories with...
-
11B-809.10.8 Lavatories, vanities, mirrors and towel bars
Bathing rooms or powder rooms required to comply with Section 11B-809.10 shall provide lavatories complying with this section. Where mirrors or towel bars are provided, no less than...
-
11B-809.10.7.4 Seat height
Water closet seats shall be 15 inches (381 mm) minimum and 19 inches (483 mm) maximum measured to the top of the seat above the finish floor.
-
11B-809.10.8.4 Knee and toe clearance
Knee and toe clearance shall be provided and comply with Section 11B-306.
-
11B-809.10.7.3 Reinforcement for grab bars
Reinforcement for grabs bars shall comply with the following: Where water closets are not placed adjacent to a side wall capable of accommodating a grab bar, the bathroom...
-
907.5.2.3.3 Group R-2
In Group R-2 occupancies required by Section 907 to have a fire alarm system, all dwelling units and sleeping units shall be provided with the capability to support visible alarm notification...
-
Why Accessibility Is Important
How many people benefit from accessible facilities?...
-
An example of an "undue burden" and how it might be solved is:
There is no space on the accessible first floor large enough to hold the meetings, there is no other building where the meetings could be held, and the cost of installing an elevator is...
-
B3. Access Aisle
Is the area for the access aisle at least 5-feet wide and 20-feet long?...
-
382.71 What other aircraft accessibility requirements apply to carriers?
382.71 What other aircraft accessibility requirements apply to carriers?...
-
[F] 907.5.2.3.4 Group R-2
In Group R-2 occupancies required by Section 907 to have a fire alarm system, all dwelling units and sleeping units shall be provided with the capability to support visible alarm notification...
-
Parking Spaces: ADA Standard Section 208
Section 208 covers scoping requirements in the most current ADA Standards for parking spaces.
-
11B-208 Parking spaces
[See subsections ...]
-
11B-208 Parking spaces
[See subsections ...]
-
1005.1 Accessible Routes
1005.1 Accessible Routes. Accessible routes serving fishing piers and platforms, including gangways and floating piers, shall comply with Chapter 4. EXCEPTIONS: 1....
-
Cross Slope [1018.7.2]
When beach access routes are constructed of asphalt, concrete, or boards, the cross slope must be no steeper than 1:48 (2 percent)....