Technical requirements state the specific numbers, conditions, and measurements that are required (percent that must comply, dimensions, reach ranges, grades, trail width, and so forth)....
Search Results "Curb Ramp Width"
-
Technical requirements
-
Side Entry: ADA Standard Section 1002.4.4.2
A 32 inch (815 mm) clear opening will not provide sufficient width when entered through a turn into an amusement ride....
-
11B-704.2.1.2 Forward approach
If an additional 6 inches (152 mm) in width of clear floor space is provided, creating a clear floor space of 36 inches by 48 inches (914 mm by 1219 mm), the enclosure may extend more than...
-
11B-1002.4.4.2 Side entry
A 32 inch (815 mm) clear opening will not provide sufficient width when entered through a turn into an amusement ride....
-
11B-704.2.1.2 Forward approach
If an additional 6 inches (152 mm) in width of clear floor space is provided, creating a clear floor space of 36 inches by 48 inches (914 mm by 1219 mm), the enclosure may extend more than...
-
11B-1002.4.4.2 Side entry
A 32 inch (815 mm) clear opening will not provide sufficient width when entered through a turn into an amusement ride....
-
Accessible Route to Dumpster and Enclosure
This would trigger: a level area outside the gate to accommodate the door maneuvering clearance, operable door/gate hardware, clear width at doorway, and compliant closer speed...
-
Pemko 193 Slip resistance
By slip resistance I am assuming it will meet the coefficient of friction requirement of 0.8 if installed on a ramp. Thank you -Brian...
-
(3) Doors within individual dwelling units
The final Guidelines recommend that doors intended for user passage within individual dwelling units have a clear opening of at least 32 inches nominal width when the door is open 90 degrees...
-
1009.6.2 Handrails
The width between handrails shall be 20 inches (510 mm) minimum and 24 inches (610 mm) maximum. Handrail extensions required by 505.10.3 shall not be required on pool stairs....
-
11B-1009.6.2 Handrails
The width between handrails shall be 20 inches (508 mm) minimum and 24 inches (610 mm) maximum....
-
1016.8 Resting Intervals
This section contains the technical requirements for the length (1016.8.1), width (1016.8.2), and slope (1016.8.3) of resting intervals; and for a turning space (1016.8.4) where resting...
-
Openings [§302.3]
Openings [§302.3] Openings in ground and floor surfaces, such as grates, are limited in width to prevent passage of a ½” diameter sphere....
-
11B-1009.6.2 Handrails
The width between handrails shall be 20 inches (508 mm) minimum and 24 inches (610 mm) maximum....
-
§ 38.153(b)
(b) All step edges shall have a band of color(s) running the full width of the step which contrasts from the step tread and riser, either dark-on-light or light-on-dark....
-
11B-1009.6.2 Handrails
The width between handrails shall be 20 inches (508 mm) minimum and 24 inches (610 mm) maximum....
-
Stairs
Requirement: 4.9.4(2) If handrails are not continuous, they shall extend at least 12 in (305 mm) beyond the top riser and at least 12 in (305 mm) plus the width of one tread beyond the...
-
407.4.1 Car Dimensions
Inside dimensions of elevator cars and clear width of elevator doors shall comply with Table 407.4.1....
-
R210.3 Shared Use Paths
require objects along or overhanging any portion of a pedestrian circulation path to comply with the proposed technical provisions for protruding objects in R402 and to not reduce the clear width...
-
Scoping [4.1.3(5)]
In new construction, platform lifts can be used instead of ramps or elevators only in providing access to: performing areas in assembly occupancies wheelchair seating locations...
-
Technical Requirements [1017]
The technical requirements for trails include specific provisions for the surface, clear tread width, passing spaces, tread obstacles, openings, running slope, cross slope, resting intervals...
-
1134A.6, Item 3
A clear maneuvering space at least 30 inches in width by 48 inches in length (762 mm by 1219 mm) shall be located outside the shower, flush and parallel to the control wall....
-
11B-705.1.2.4 Bus stops
When detectable warnings are provided at bus stop boarding and alighting areas, the detectable warnings shall extend the full width of the boarding/alighting area and shall be 36 inches...
-
§ 38.107(b)
accessible shall be in close proximity to at least one seating location for persons using mobility aids and shall be connected to such a space by an unobstructed path having a minimum width...