Safety (smoke- and CO-alarm installations and fire-safety education), and Critical Needs (primarily accessibility ramps and, if emergency funding permits, assistance with roofs, heat/hot water...
Search Results "Water Spray Unit"
Commonly Searched Documents
- Rebuilding Together North Jersey - Ridgewood, NJ
-
Regulatory Process Matters
Minimum clearance at water closet in accessible single user toilet rooms: 60 x 56 inches....
-
Implementation and Enforcement
The United States may review LCG’s compliance with this Agreement or title III of the ADA at any time. ...
-
2.2
2.2 This Consent Order shall be a full, complete, and final disposition and settlement of all of the United States' and Cinemark's claims between the parties that have arisen in this...
-
§27.125(a)(1)
(1) A referral to the Department of Justice with a recommendation that appropriate proceedings be brought to enforce any rights of the United States under any law of the United States (including...
-
1(3)(a)(i)
(i) Where a building elevator is provided only as a means of creating an accessible route to dwelling units on a ground floor, the building is not considered an elevator building for purposes...
-
1(3)(a)
(a) There is an elevator connecting the parking area with the dwelling units on a ground floor....
-
§100.305(e)(5)(i)
(i) Has reserved all unoccupied units for occupancy by at least one person 55 years of age or older until at least 80 percent of the units are occupied by at least one person who is 55 years...
-
VI. IMPLEMENTATION AND ENFORCEMENT OF AGREEMENT
If, after further discussion with Olympia, the United States believes that Olympia has violated the Settlement Agreement, the United States may institute a civil action for relief in federal...
-
Forward Approach
For wheelchair access, the proposed rule required a forward approach at cantilevered units but allowed a parallel approach at other types of units, such as those that are floor mounted....
-
11B-806.2.4 Toilet and bathing facilities
No fewer than one water closet, one lavatory, and one bathtub or shower shall comply with applicable requirements of Sections 11B-603 through 11B-610....
-
Fur out the wall
The water closet shall be positioned with a wall or partition to the rear and to one side....
-
11B-1005.2.1.1 Dispersion
Different fishing locations may provide varying water depths, shade (at certain times of the day), vegetation, and proximity to the shoreline or bank....
-
11B-807.2.4 Toilet and bathing facilities
Where provided, no fewer than one water closet, one lavatory, and one bathtub or shower shall comply with the applicable requirements of Sections 11B-603 through 11B-610....
-
602 Drinking Fountains
Substantive changes to this section include: removal of references to water coolers (602.1) requiring all wheelchair accessible drinking fountains to provide knee and toe...
-
1009.2.3 Clear Deck Space
On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat....
-
Gangways
gangways are provided as part of accessible routes to connect floating accessible fishing piers or platforms, the following exceptions to ADAAG have been included to deal with the varying water...
-
Accessible Pool Stairs
Accessible Pool Stairs Accessible pool stairs are designed to provide assistance with balance and support from a standing position when moving from the pool deck into the water and out...
-
Footrests and Armrests
Armrests are not required, however if provided, the armrest opposite the water must be removable or be able to fold clear of the seat when the seat is in the raised (load) position....
-
Sinks [F212.3, Exception 2]
When hot water is provided, the drainpipes at sinks and lavatories must be wrapped, insulated, or shielded to help prevent a person using a mobility device from accidentally touching the...
-
11B-1005.2.1.1 Dispersion
Different fishing locations may provide varying water depths, shade (at certain times of the day), vegetation, and proximity to the shoreline or bank....
-
11B-604.7.1 Dispensers
Toilet paper dispensers shall comply with Section 11B-309.4 and shall be 7 inches (178 mm) minimum and 9 inches (229 mm) maximum in front of the water closet measured to the centerline of...
-
11B-807.2.4 Toilet and bathing facilities
Where provided, no fewer than one water closet, one lavatory, and one bathtub or shower shall comply with the applicable requirements of Sections 11B-603 through 11B-610....
-
11B-1005.2.1.1 Dispersion
Different fishing locations may provide varying water depths, shade (at certain times of the day), vegetation, and proximity to the shoreline or bank. ◼...