(d) If an inspection under Subsection (c) determines that a building or facility does not comply with all applicable standards and specifications, the leasing agency or the Texas Building...
Search Results "State Building Code"
-
Sec. 469.106(d)
-
4.1.3(9)*
(9)* In buildings or facilities, or portions of buildings or facilities, required to be accessible, accessible means of egress shall be provided in the same number as required for exits...
-
Interim Segway® Personal Transporter Policy
To that end, GSA's Public Buildings Service is issuing this interim policy to permit individuals with a mobility impairment to use these devices in Federal buildings under GSA’s jurisdiction...
-
surface mounted toilet paper dispensers
Although best practices used to include recessed or semi-recessed toilet paper dispensers adjacent to disabled accessible water closets, the codes appear to be silent on this as a requirement...
-
Re: Section 307 Protruding Objects
Yes, it is a protruding object hazard based solely on section 307, but so is the (code compliant) lavatory with its (required) 29" high front edge, and the 8" deep (code compliant) shelf...
-
11B-104.1 Dimensions
Dimensions that are not stated as "maximum" or "minimum" are absolute. Advisory 11B-104.1 Dimensions. This section clarifies the dimensioning conventions used in this chapter. ...
-
11B-104.1 Dimensions
Dimensions that are not stated as “maximum” or “minimum” are absolute. Advisory 11B-104.1 Dimensions. This section clarifies the dimensioning conventions used in this chapter. ...
-
11B-104.1 Dimensions
Dimensions that are not stated as “maximum” or “minimum” are absolute. Advisory 11B-104.1 Dimensions. This section clarifies the dimensioning conventions used in this chapter....
-
Section 36.403 Alterations: Path of Travel
Proposed Sec. 36.403(a)(1) stated that if a private entity has constructed or altered required elements of a path of travel in accordance with the 1991 Standards, the private entity is not...
-
Minimum Clear Opening
Commenters from the building industry were almost unanimous in their opposition to a minimum clear opening of 32 inches....
-
‘‘Facility.’’ (Preamble, Section-by-Section Analysis)
"Facility'' means all or any portion of buildings, structures, sites, complexes, equipment, rolling stock or other conveyances, roads, walks, passageways, parking lots, or other real or...
-
Facility (Section-By-Section Analysis and Response to Comments)
"Facility'' means all or any portion of buildings, structures, sites, complexes, equipment, rolling stock or other conveyances, roads, walks, passageways, parking lots, or other real or...
-
Occupant Load
The number of persons for which the means of egress of a building or portion of a building is designed....
-
106.5.39 Occupant Load
The number of persons for which the means of egress of a building or portion of a building is designed....
-
Key Operation
Previous editions of the safety code for lifts, not the Board’s guidelines, required platform lifts to be key operated....
-
BACKGROUND
The United States states that HWI is a “public accommodation” within the meaning of Title III of the Americans with Disabilities Act (“ADA”), 42 U.S.C. § 12181(7)(A), and 28 C.F.R. §36.104...
-
225(c)(2)
(2) with respect to intrastate telecommunications relay services in any State that has a certified program under subsection (f) of this section for such State, if such common carrier (or...
-
Slope: ADA Standard Section 405.2
Section 405.2 covers the current ADA Standards for slope requirements on ramps.
-
1009.7.2 Separation
Exterior walls separating the exterior area of assisted rescue from the interior of the building shall have a minimum fire-resistance rating of 1 hour, rated for exposure to fire from the...
-
1009.7.2 Separation
Exterior walls separating the exterior area of assisted rescue from the interior of the building shall have a minimum fire-resistance rating of 1 hour, rated for exposure to fire from the...
-
11B-504.8 Floor identification
Sections 11B-703.1, 11B-703.2, 11B-703.3 and 11B-703.5 shall be located at the landing of each floor level, placed adjacent to the door on the latch side, in all enclosed stairways in buildings...
-
11B-504.8 Floor identification
Sections 11B-703.1, 11B-703.2, 11B-703.3 and 11B-703.5 shall be located at the landing of each floor level, placed adjacent to the door on the latch side, in all enclosed stairways in buildings...
-
Industry Standards
construction—Tolerances for building—Part 1: Basic principles for evaluation and specification ISO 3443-2 Building construction—Tolerances for building—Part 2: Statistical...
-
Finding Sign Language Interpreters
State agencies: Not all freelance interpreters are members of RID....