Section 407.2.2.2 covers the current ADA Standards for elevator visible signals.
Search Results "Raised Judging Area"
Commonly Searched Documents
-
Visible Signals: ADA Standard Section 407.2.2.2
-
11B-407.2.1.2 Size and shape
Call buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in the smallest dimension and shall be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding...
-
Signs
Signs • Signs that identify permanent rooms and spaces, such as those identifying rest rooms, exits or room numbers, must have Braille and raised letters or numbers so that they may be...
-
Adjustable height protocol
The amount of vertical distance that the seat was raised/lowered each time depended on the subject’s perceived and observed transfer abilities....
-
Section 2. Slope
For example, if a principal entrance is ten feet from a passenger loading zone, and the principal entrance is raised one foot higher than the passenger loading zone, then the slope is 1/...
-
4.29.2* Detectable Warnings on Walking Surfaces
Detectable warnings shall consist of raised truncated domes with a diameter of nominal 0.9 in (23 mm), a height of nominal 0.2 in (5 mm) and a center-to-center spacing of nominal 2.35 in...
-
Is there a minimum distance between changes in level?
Such level changes may need to be in close proximity, such as at raised thresholds (otherwise a minimum 48” separation will provide enough wheelchair space so that only one vertical change...
-
11B-407.2.1.2 Size and shape
Call buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in the smallest dimension and shall be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding...
-
11B-703.5 Visual characters
Exception: Where visual characters comply with Section 11B-703.2 _|Signs; Raised Characters|_ and are accompanied by Braille complying with Section 11B-703.3, they shall not be required...
-
11B-707.9.1.1 Tactilely discernible numerical keypad
A tactilely discernible numerical keypad similar to a telephone keypad containing a raised dot with a dot base diameter between 1.5 mm and 1.6 mm and a height between 0.6 mm and 0.9 mm on...
-
11B-407.2.1.2 Size and shape
Call buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in the smallest dimension and shall be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding...
-
Appendix D: Photometric Measurements
Where: L1 is the luminance of the lighter area and L2 is the luminance of the darker area....
-
Amusement Ride
A system that moves persons through a fixed course within a defined area for the purpose of amusement....
-
ADDITION
[DSA-AC] An expansion, extension or increase in the gross floor area or height of a building or facility....
-
11B-812.8.6 Finish and size
Identification signs shall be reflectorized with a minimum area of 70 square inches (45161 mm2)....
-
11B-219.5 Permanent and portable systems
Permanently installed assistive-listening systems are required in areas if (1) they accommodate at least 50 persons or if they have audio-amplification systems, and (2) they have fixed seating...
-
Implementation and Enforcement
If the United States believes that this Agreement or any portion of it has been violated, it will raise its concerns with LCG and the parties will attempt to resolve the concerns in good...
-
WET BAR
[DSA-AC] An area or space with a counter equipped with a sink and running water but without cooking facilities....
-
11B-502.6.1 Finish and size
Parking identification signs shall be reflectorized with a minimum area of 70 square inches (45,161 mm2)....
- ADA Sign Depot Wheelchair Accessible Restroom Sign with Directional Arrow - Tactile Text, Symbols, and Grade 2 Braille
- The Spa Lift Ultra™ Pool & Spa Access Lift
-
General: ADA Standard Section 216.1
Section 216.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for signs.
-
11B-209.5 Mechanical access parking garages
Mechanical access parking garages shall provide at least one passenger drop-off and loading zone complying with Section 11B-503 at vehicle drop-off and vehicle pick-up areas....
-
11B-233.3.1.2.6.2 Test number one, individual building test
For purposes of these requirements, vehicular or pedestrian site arrival points include public or resident parking areas, public transportation stops, passenger loading zones and public...