The height of transfer platforms shall be 11 inches (280 mm) minimum and 18 inches (455 mm) maximum measured to the top of the surface from the ground or floor surface....
Search Results "Surface Slope"
-
Height: ADA Standard Section 1008.3.1.2
-
Blended Transitions (R304.4) (Section-by-Section Analysis)
Blended Transitions (R304.4) (Section-by-Section Analysis) A maximum running slope of 5 percent is specified for blended transitions....
-
Camp Shelters
Ensure that the surface of the clear floor or ground space at the open entrance side of the shelter and the floor of the shelter is firm, stable, and does not slope more than 2 percent (...
-
1131B.2, Item 1
Vehicle standing spaces and access aisles shall be level with surface slopes not exceeding one unit vertical in 50 units horizontal (2-percent slope) in all directions....
-
1010.1.5 Floor elevation
Landings shall be level except for exterior landings, which are permitted to have a slope not to exceed 0.25 unit vertical in 12 units horizontal (2-percent slope)....
-
11B-406.3 Parallel curb ramps
A parallel curb ramp may be provided with one sloping segment or two opposing sloping segments....
-
R202.3.3 Reduction in Access Prohibited
Sidewalk improvements that correct existing excessive cross slope should be carefully planned to avoid creating excessive slope in curb ramps or adding a step at existing building entrances...
- Lift-U® Fold-Out Ramp Plus
-
Construction Specification Institute
Construction Specification Institute While developing suggested tolerances for surface materials, the Construction Specifications Institute developed a suggested method for measuring ramp...
- AJW Architectural Products U716 Series 16"W x 20"H Channel Frame Mirror w/ Mounted Shelf - Plate Glass Surface
- AJW Architectural Products U705 Series 16"W x 30"H Angle Frame Mirror w/ Mounted Shelf - Plate Glass Surface
-
Top Landing [§406.4]
Side flare slopes cannot exceed 1:10 max. (or 1:12 max. in alterations where a top landing is unavailable)....
-
Nosings: ADA Standard Section 504.5
Section 504.5 covers the current ADA Standards for stair nosings.
-
Parallel Curb Ramps (R304.3) (Section-by-Section Analysis)
Parallel Curb Ramps (R304.3) (Section-by-Section Analysis) Parallel curb ramps have a running slope that is in-line with the direction of sidewalk travel and lower the sidewalk to a level...
- Corbin Russwin Inc. BLSS Trim Lever Handle & Lockset
-
1132A.4.1, Item 2
Thresholds with a change in height between ¼ inch (6.35 mm) and ¾ inch (19.05 mm) shall be beveled with a slope no greater than 1 unit vertical in 2 units horizontal (50-percent slope)....
-
Parallel Approach: ADA Standard Section 904.4.1
A portion of the counter surface that is 36 inches (915 mm) long minimum and 36 inches (915 mm) high maximum above the finish floor shall be provided....
-
1132A.4.1, Item 2
Thresholds with a change in height between ¼ inch (6.35 mm) and 3/4 inch (19.05 mm) shall be beveled with a slope no greater than 1 unit vertical in 2 units horizontal (50-percent slope)...
-
Story
That portion of a building or facility designed for human occupancy included between the upper surface of a floor and upper surface of the floor or roof next above....
-
11B-404.2.5 Thresholds
[2010 ADA Standards] EXCEPTION: Existing or altered thresholds ¾ inch (19 mm) high maximum that have a beveled edge on each side with a slope not steeper than 1:2 shall not be required...
-
11B-404.2.5 Thresholds
[2010 ADA Standards] EXCEPTION: Existing or altered thresholds ¾ inch (19 mm) high maximum that have a beveled edge on each side with a slope not steeper than 1:2 shall not be required...
-
11B-1009.4.1 Clear deck space
A clear deck space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
Clear Deck Space: ADA Standard Section 1009.4.1
A clear deck space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
11B-1009.4.1 Clear deck space
A clear deck space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....