A substantial alteration to a kitchen or bathroom includes, but is not limited to, alterations that are changes to or rearrangements in the plan configuration, or replacement of cabinetry...
Search Results "Floor Plan"
Commonly Searched Documents
-
233.3.4.2 Alterations to Individual Residential Dwelling Units
-
RETURNING HOME
In case temporary housing is needed past the stay at the shelter, your emergency response plan could identify available physically accessible short-term housing, as well as housing with...
-
11B-206.2.3 Multi-story buildings and facilities
For example, a 3-story office building with 4500 sf on the first floor, 2500 sf on the second floor and 1500 sf on the third floor would not qualify for the exception because one of the...
-
11B-206.2.3 Multi-story buildings and facilities
For example, a 3-story office building with 4500 sf on the first floor, 2500 sf on the second floor and 1500 sf on the third floor would not qualify for the exception because one of the...
-
11B-206.2.3 Multi-story buildings and facilities
For example, a 3-story office building with 4500 sf on the first floor, 2500 sf on the second floor and 1500 sf on the third floor would not qualify for the exception because one of the...
-
1124B
One full unobstructed side of the clear floor or ground space for a wheelchair shall adjoin or overlap an accessible route or adjoin another wheelchair clear floor space....
-
Initial Measures and Transfer Setup
The device seat to floor height was measured as the linear distance between the front of the seat, center-line point on top of the cushion (if present) and the floor (Figure 3 left). ...
-
M303.2.4.2.2 Height
Wheelchair spaces shall include toe clearance 9 inches (230 mm) high minimum above the floor measured to a depth of 6 inches (150 mm) maximum measured from the toe end of the wheelchair...
-
Elevators
Elevators Common Problem: Lodging facilities with more than two floors of occupiable space - including any basement levels - do not have full-size passenger elevators available for...
-
Definition of "Mezzanine"
"Mezzanine" is now defined by the same definition used in the IBC: "An intermediate level or levels between the floor and ceiling of any story with an aggregate floor area of not more than...
-
5.8.2.7 Base Support Allowance
Base support is permitted to obstruct the clear floor space if it fits within the allowed base support volume. Base supports can be a maximum of 1½ inches high....
-
M9
Does the lavatory have at least a 29-inch-high clearance under the front edge and the top of the rim no more than 34 inches above the floor?...
-
What about a service animal that is not accompanying a qualified individual with a disability?
Individuals planning to travel with a service animal other than their own should inquire about the applicable policies in advance....
-
Audio description of exhibits
The Museum will continue to offer its existing twenty-minute tactile orientation tour with advance notice pending completion of its plan to provide a qualified audio describer who can audio...
-
(11) the City's ongoing failure to adopt any written policy or procedure
Aside from a brief reference to the adequacy of the City's transition plan, the FAC does not specifically reference any of the above policies. Dkt. 294, ¶ 44....
-
Sec.36.402(b)(1)
limited to, remodeling, renovation, rehabilitation, reconstruction, historic restoration, changes or rearrangement in structural parts or elements, and changes or rearrangement in the plan...
-
II. Public Hearing
The Department plans to hold the public hearing during the 180-day public comment period....
-
§1630.14(d)(4)(iii)
(iii) Except as permitted under paragraph (d)(4)(i) of this section and as is necessary to administer the health plan, information obtained under this paragraph (d) regarding the medical...
-
How is “technical infeasibility” determined in an alteration?
Determining “technical infeasibility” requires a site-specific assessment of constraints or complications in relation to the planned scope of work....
-
11B-404.2.7 Door and gate hardware
Operable parts of such hardware shall be 34 inches (864 mm) minimum and 44 inches (1118 mm) maximum above the finish floor or ground....
-
11B-306.2.1 General
Space under an element between the finish floor or ground and 9 inches (229 mm) above the finish floor or ground shall be considered toe clearance and shall comply with Section 11B-306.2...
-
e-iv
Are the highest floor control buttons mounted no more than 54 inches above the floor for a side reach or 48 inches for forward reach? [ADA Standards § 4.10.12 (3)] Yes No...
-
306.2.1 General
Space under an element between the finish floor or ground and 9 inches (230 mm) above the finish floor or ground shall be considered toe clearance and shall comply with 306.2....
-
11B-306.2.1 General
Space under an element between the finish floor or ground and 9 inches (229 mm) above the finish floor or ground shall be considered toe clearance and shall comply with Section 11B-306.2...