The top of bathtub seats shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum above the bathroom finish floor....
Search Results "Floor Destination Indicator"
Commonly Searched Documents
-
11B-610.2 Bathtub seats
-
11B-903.6 Structural strength
Benches shall be affixed to the wall or floor....
-
11B-411.2.3.2 Car designation signs
Car designation signs complying with Sections 11B-703.2 and 11B-703.4.1 shall be provided on both jambs of the hoistway immediately below the floor designation....
-
F206.2.3 Multi-Story Buildings and Facilities
However, if the laundry room on the first floor is restricted to use by residents on the first floor, and the second floor laundry room is for use by occupants of the second floor, then...
-
L. Controls
Are all drapery control wands, fixed lamps and HVAC controls in accessible guestrooms placed within 54" of the floor for side approach or 48" of the floor for forward approach so persons...
-
4.34.6.4(1)
(1) The counter shall be mounted at a maximum height of 34 in (865 mm) above the floor, measured from the floor to the top of the counter surface, or shall be adjustable or replaceable as...
-
11B-703.3.1 Dimensions and capitalization
The indication of an uppercase letter or letters shall only be used before the first word of sentences, proper nouns and names, individual letters of the alphabet, initials, and acronyms...
-
9.6 ATTENDANCE-RECORDING EQUIPMENT
racks, log books, and other work assignment or attendance-recording equipment used by people in wheelchairs must be installed at a height no more than 48 in (1220 mm) above the finished floor...
-
1134A.7 Water closets
Floor space and location. The minimum floor space provided at a water closet shall be 48 inches (1219 mm) in clear width. ...
-
308.3.1 Unobstructed
Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1220 mm) maximum and the low side...
-
E2-1. Pedestrian Routes
pedestrian routes leading to or serving the voting area free of objects that protrude from the side more than 4 inches into the route with the bottom of the object more than 27 inches above the floor...
-
4.5.3* CARPET
If carpet or carpet tile is used on a ground or floor surface, then it shall be securely attached; have a firm cushion, pad, or backing or no cushion or pad; and have a level loop, textured...
-
11B-603.3 Mirrors
Mirrors located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 40 inches (1016 mm) maximum above the finish floor or ground....
-
11B-603.4 Coat hooks, shelves and medicine cabinets
Shelves shall be located 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor....
-
5.8.2.1 Height of Breast Platform at Time of Measurement
Breast Platform at Time of Measurement Recommendation The Committee recommends measuring all knee and toe clearances when the top of the breast platform is set at 34 inches above the floor...
-
611.4 Height
Top loading machines shall have the door to the laundry compartment located 36 inches (915 mm) maximum above the finish floor....
-
4(5)
(5) Exterior deck, patio, or balcony surfaces are no more than 1/2 inch below the floor level of the interior of the dwelling unit, unless they are constructed of impervious material such...
-
Accessible Route
Interior accessible routes may include corridors, floors, ramps, elevators, lifts, and clear floor space at fixtures....
-
4.2.1 General
In alterations, where a condition for exception in section 1.1 prohibits full compliance with a specific requirement for clear floor or ground space surface, slope, size, or location, the...
-
4.34.6.5(7)
(7) A clear floor space 30 in by 48 in (760 mm by 1220 mm) shall allow forward approach to the sink....
-
11B-611.4 Height
Top loading machines shall have the door to the laundry compartment located 36 inches (914 mm) maximum above the finish floor....
- Gamco Automatic Wall-Mounted Foam Soap Dispenser - G-950FA
-
Issue 1: APS volume
It is common to find APS volumes set so loud that the pushbutton locator tone and audible walk indication can be heard at midblock or across the street -- or in a quiet office or bedroom...
-
Directional visual sign vs. room identification tactile sign
The arrow appears to indicate that this specific sign is a directional sign pointing toward the location of an accessible toilet room. ...