(b) Bathrooms that have reinforced walls for grab bars (see Requirement 6) would meet section 100.205(c)(3)(iv) if: Note: Clear floor space beside tub may overlap with clear floor...
Search Results "Door Opening Force"
-
7(2)(b)
- Rockwood Manufacturing Company 619 UL Listed 160˚ Door Viewer For Doors 11/16" to 1-1/16"
-
11B-403.5.1 Clear width
The clear width for accessible routes to accessible toilet compartments shall be 44 inches (1118 mm) except for door-opening widths and door swings....
-
11B-403.5.1 Clear width
The clear width for accessible routes to accessible toilet compartments shall be 44 inches (1118 mm) except for door-opening widths and door swings....
-
611.4 Height
Top loading machines shall have the door to the laundry compartment located 36 inches (915 mm) maximum above the finish floor....
-
§ 38.101(b)
(b) The doorways of cars not operating at lighted station platforms shall have outside lights which, when the door is open, provide at least 1 footcandle of illumination on the station platform...
-
11B-611.4 Height
Top loading machines shall have the door to the laundry compartment located 36 inches (914 mm) maximum above the finish floor....
-
1134A.5 Bathtubs
The force required to activate controls shall be no greater than 5 pounds (22.2N)....
- Rockwood Manufacturing Company 622 UL Listed 190˚ Door Viewer For Doors 1-3/8" to 2-1/8"
-
4.1.6(3)(c)(iii)
For example, an elevator of 47 in by 69 in (1195 mm by 1755 mm) with a door opening on the narrow dimension, could accommodate the standard wheelchair clearances shown in Figure 4....
-
11B-611.4 Height
Top loading machines shall have the door to the laundry compartment located 36 inches (914 mm) maximum above the finish floor....
-
§ 38.119(b)
(b) The doorways of cars not operating at lighted station platforms shall have outside lights which, when the door is open, provide at least 1 foot-candle of illumination on the station...
-
11B-504.8 Floor identification
They must be tactile, and located at the latch side of the door inside the stairway as prescribed by CBC Section 11B-703.4....
-
11B-504.8 Floor identification
They must be tactile, and located at the latch side of the door inside the stairway as prescribed by CBC Section 11B-703.4....
- Access Board: Tactile Sign Scoping
-
Area of Refuge Identification [IBC §1007.6.5 (2003), §1003.2.13.5.5 (2000)]
The IBC requires that doors providing access to areas of refuge be identified by a sign that includes the term “AREA OF REFUGE” and the International Symbol of Accessibility (ISA)....
- uberASSIST
-
1134A.8, Item 4.3
Doors to the cabinet beneath the lavatory shall be removable or openable to provide the required unobstructed knee and toe space....
-
Section 508
Section508.gov opening doors logo....
-
1134A.8, Item 4.3
Doors to the cabinet beneath the lavatory shall be removable or openable to provide the required unobstructed knee and toe space....
-
§ 38.31(c)
(c) The vehicle doorways, including doorways in which lifts or ramps are installed, shall have outside light(s) which, when the door is open, provide at least 1 foot-candle of illumination...
-
Signage
If Braille and raised letter signs are mounted on doors instead of walls, blind persons and persons with low vision may be hurt by someone who is pushing a door open while they are trying...
-
General: ADA Standard Section 229.1
Section 229.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for windows.