Visual Alarms, Notification Devices and Telephones [9.3] Auxiliary Alarms A portion of sleeping units in transient lodging facilities must have a visual alarm connected to the building...
Search Results "Unit of Measurement"
Commonly Searched Documents
-
Visual Alarms, Notification Devices and Telephones [9.3] Auxiliary Alarms
-
BACKGROUND
The parties (“Parties”) to this Settlement Agreement (“Agreement”) are the United States of America (“United States”) and Associated Foot & Ankle Centers of Northern Virginia, PC (“AFAC...
-
Notes
C Each year, the National Healthcare Disparities Reports look at different measures of disparities, such as different types of service use or different measures of patients’ experiences...
-
11B-703.2.5 Character height
Character height measured vertically from the baseline of the character shall be 5/8 inch (15.9 mm) minimum and 2 inches (51 mm) maximum based on the height of the uppercase letter “I”. ...
-
406.8 Detectable Warnings
The detectable warning shall extend the full width of the curb ramp (exclusive of flared sides) and shall extend either the full depth of the curb ramp or 24 inches (610 mm) deep minimum measured...
-
Intensity
Lamp intensity is given in effective candela (cd), measured in use at the source....
-
§ 38.23(b)(8) Platform entrance ramp
The entrance ramp, or loading-edge barrier used as a ramp, shall not exceed a slope of 1:8, measured on level ground, for a maximum rise of 3 inches, and the transition from roadway or sidewalk...
- Ampetronic CLD1 Compact Small Area & Counter Induction Loop Driver Hearing System
-
F213.2 Toilet Rooms and Bathing Rooms
Where multiple single user portable toilet or bathing units are clustered at a single location, no more than 5 percent of the toilet units and bathing units at each cluster shall be required...
-
213.2 Toilet Rooms and Bathing Rooms
Where multiple single user portable toilet or bathing units are clustered at a single location, no more than 5 percent of the toilet units and bathing units at each cluster shall be required...
-
213.2 Toilet Rooms and Bathing Rooms
Where multiple single user portable toilet or bathing units are clustered at a single location, no more than 5 percent of the toilet units and bathing units at each cluster shall be required...
- 1100KL EHR Digital Platform Scale with Extra Wide Handrails and Digital Height Rod
- 1100KL HR Digital Platform Scale Extra Wide Handrail with Mechanical Height Rod
- 1100KL BT Digital Platform Scale Extra Wide Handrails and Built-in Pelstar® Wireless Technology
-
EXHIBIT A Required Accessible Elements at QuikTrip Stores
Doors shall have a clear opening at least 32 inches wide when measured from the face of the door to the opposite stop when the door is opened 90 degrees and shall have hardware usable with...
-
302 Floor or Ground Surfaces
Historically, the Board has not specified a particular level of slip resistance since it can be measured in different ways....
-
11B-903.4 Back support
Back support shall be 2½ inches (64 mm) maximum from the rear edge of the seat measured horizontally. [2010 ADAS] 903.4 Back Support. ...
-
1117B.5.3
Characters on signs shall be selected from fonts that have a width-to-height ratio of between 3:5 (60 percent) and 1:1 (100 percent) measured by the width of the uppercase letter "O" and...
-
Transit Stops (R308.1) (Section-by-Section Analysis)
Transit Stops (R308.1) (Section-by-Section Analysis) Boarding and alighting areas at sidewalk or street level transit stops must be 2.4 meters (8 feet) minimum measured perpendicular...
-
Literature Review
The second topic was to explore ways to measure, design, and monitor the quality of pathway surfaces for WC users. Therefore two separate searches were conducted....
-
Accessible Pathway & Corridor: Minimum Clear Width Required for 180-degree Turn
Findings from the Anthropometry of Wheeled Mobility Study indicate that a width of at least 130 cm (51 in.) was required for 50% of the manual wheelchair users measured in this study to...
-
Accessible Pathway & Corridor: Minimum Clear Width Required for 180-degree Turn Around Barrier
Findings from the Anthropometry of Wheeled Mobility Study indicate that a uniform width of at least 89.5 cm (35 in.) was required for 50% of the manual and power wheelchair users measured...
- Diversified Woodcrafts 9010 ARM Lab Table Accessory
-
References
Presented to the United States Access Board September 2010. http://herl.pitt.edu/ab/....