We value and cherish every person that walks through our door and are determined to help them to the best of our ability....
Search Results "Door Closer"
Commonly Searched Documents
- Peninsula CIL/Insight Enterprises, Inc. (PCIL) - Hampton, VA
-
11B-611.4 Height
Top loading machines shall have the door to the laundry compartment located 36 inches (914 mm) maximum above the finish floor....
-
611.4 Height
Top loading machines shall have the door to the laundry compartment located 36 inches (915 mm) maximum above the finish floor....
-
233.3.6
duplexes, triplexes, condominiums, and townhouses shall provide at least one bathroom, located with maximum possible privacy, where bathrooms are provided on habitable grade levels, with a door...
-
F213.2.1 Unisex (Single-Use or Family) Toilet and Unisex Bathing Rooms
Doors to unisex toilet rooms and unisex bathing rooms shall have privacy latches....
-
213.2.1 Unisex (Single-Use or Family) Toilet and Unisex Bathing Rooms
Doors to unisex toilet rooms and unisex bathing rooms shall have privacy latches....
-
1134A.8, Item 4.3
Doors to the cabinet beneath the lavatory shall be removable or openable to provide the required unobstructed knee and toe space....
-
Section 508
Section508.gov opening doors logo....
-
1134A.8, Item 4.3
Doors to the cabinet beneath the lavatory shall be removable or openable to provide the required unobstructed knee and toe space....
-
§ 38.31(c)
(c) The vehicle doorways, including doorways in which lifts or ramps are installed, shall have outside light(s) which, when the door is open, provide at least 1 foot-candle of illumination...
-
11B-405.8 Handrails
At door landings, handrails are not required on ramp runs less than 6 inches (152 mm) in rise or 72 inches (1829 mm) in length....
-
11B-206.4 Entrances
Entrance doors, doorways, and gates shall comply with Section 11B-404 and shall be on an accessible route complying with Section 11B-402. Exceptions: 1. Reserved....
-
11B-604.3.1 Size
Note The CBC 11B-604.3.1 requirement for maneuvering space in front of accessible water closets exceeds the 2010 ADA Standards requirement for water closet clear floor space, but a door...
-
Best Bath Systems ADL Spa Electronic Touch Control Series Slide-Door Bath Tub Details
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Material Characteristics (slide 6)
But now it’s hard for people to find which ones of those [glass panels] are doors....
-
1022.9 Stairway identification signs
comply with Chapter 11A, Section 1143A or Chapter 11B, Sections 11B-703.1, 11B-703.2, 11B-703.3 and 11B-703.5 shall be located at the landing of each floor level, placed adjacent to the door...
-
A. Accessible Voting Program
facilities and equipment (including, but not limited to, permanent equipment such as lifts and elevators, and temporary equipment such as portable ramps, traffic cones, signs, wedges, and door...
-
II-6.5000 Alterations to historic properties
There appears, however, to be a problem if one of the interior doors is widened, because historic decorative features on the door might be destroyed....
-
1134A.5 Bathtubs
Doors and panels of bathtub enclosures shall be substantially constructed from approved, shatter-resistant materials. Hinged doors shall open outward....
-
Issue 2: Location relative to the crosswalk
Remedy: One solution is to move the pole closer to the crosswalk lines, so the device is in reach of the landing of the curb ramp and adjacent to the crosswalk....
-
Grab bars
The 2.75-inch was added to examine the effects of a handheld when located closer to the transfer surface. ...
-
11B-208.3.1 General
For example, accessible spaces required for outlying parking facilities may be located in a parking facility closer to an accessible entrance....
-
R302.2 Components
Doors, doorways, and gates complying with section 404 of Appendix D to 36 CFR part 1191. Advisory R302.2 Components....
-
City of XXX – ADA Transition Plan
Facilities manager $450 Maintenance and repairs City Council room Inadequate maneuvering clearance at entrance door...