Symphony® seamlessly integrates a full range of Grade 1 Yale electromechanical hardware - from mortise locks to cylindrical locks and exit devices - into your Wiegand access control system...
Search Results "Door Control"
- Yale Symphony® Integrated Wiegand Solution
-
Operable Parts
Status Indicators—We asked whether locking or toggle controls should be discernible visually as well as by touch or sound....
-
404.2.4.4 Floor or Ground Surface
404.2.4.4 Floor or Ground Surface. Floor or ground surface within required maneuvering clearances shall comply with 302. Changes in level are not permitted. EXCEPTIONS: 1. Slopes...
-
11B-404.2.4.4 Floor or ground surface
Floor or ground surface within required maneuvering clearances shall comply with Section 11B-302. Changes in level are not permitted. Exceptions: 1.     Slopes not steeper...
-
404.2.4.4 Floor or Ground Surface
Floor or ground surface within required maneuvering clearances shall comply with 302. Changes in level are not permitted. EXCEPTIONS: 1. Slopes not steeper than 1:48 shall be...
-
Wheelchair Accessible Gates
Web sites with designs that allow wheelchair access while restricting access by ATVs and motorcycles are listed near the end of this tech tip. The best Web site was that of Scottish...
-
404.2.4.4 Floor or Ground Surface
Floor or ground surface within required maneuvering clearances shall comply with 302. Changes in level are not permitted. EXCEPTIONS: 1. Slopes not steeper than 1:48 shall be...
-
10.4.1(5)
(5) Baggage check-in and retrieval systems shall be on an accessible route complying with 4.3, and shall have space immediately adjacent complying with 4.2.4. If unattended security...
-
4.1.6(3)(d)(i)
(i) Where it is technically infeasible to comply with clear opening width requirements of 4.13.5, a projection of 5/8 in maximum will be permitted for the latch side stop.
-
11B-404.2.4.4 Floor or ground surface
Floor or ground surface within required maneuvering clearances shall comply with Section 11B-302. Changes in level are not permitted. Exceptions: 1. Slopes not steeper than...
- CRL Jackson 1200 Series Push Pad Door Exit Devices
-
3.5.2.1 Enforceable Accessible Parking Spaces
To be enforceable at accessible parking spaces, the ISA must comply with the Manual on Uniform Traffic Control Devices (MUTCD) section 2B.35, which requires the ISA to be displayed in blue...
- HEWI Range 180 Glass Door Hardware
- Corbin Russwin Inc. Access 800 AC2 Electrified Door Hardware
- Lutron Caséta Wireless Dimmers and Switches
- Corbin Russwin Inc. Access 600 RNE1 Electrified Door Hardware
-
3) Where the standard says "Changes in level are not permitted", but no advisory follows the standard
3) Where the standard says "Changes in level are not permitted", but no advisory follows the standard, such as 404.2.4.4 floor or ground surfaces at doors: Although the Advisory at 304.2...
- BEST B.A.S.I.S.® G Door Lever Hardware with Magnetic Stripe Reader
-
Plan 2B: 13-Foot Wide Accessible Guest Room
Features include an alternate roll-in shower with a seat, comparable vanity, wardrobe, and door connecting to adjacent guest room. Furnishings include two beds. Â ...
-
Controls: ADA Standard Section 804.6.5.3
Ovens shall have controls on front panels....
-
LaCantina Aluminum Wood Slider System Flush Sill
Requires the Premium User plan or above. (Login or upgrade your account!)
-
LaCantina Aluminum Slider System Flush Sill
Requires the Premium User plan or above. (Login or upgrade your account!)
-
LaCantina Aluminum Wood Slider System Weather Resistant Sill
Requires the Premium User plan or above. (Login or upgrade your account!)
-
LaCantina Aluminum Wood Slider System Model
Requires the Premium User plan or above. (Login or upgrade your account!)