Search Results "Ceiling Mounted Patient Lift"
-
WHEELCHAIR
-
4.10.3 Hall Call Buttons
Objects mounted beneath hall call buttons shall not project into the elevator lobby more than 4 in (100 mm)....
-
4.13.9* Door Hardware
Hardware required for accessible door passage shall be mounted no higher than 48 in (1220 mm) above finished floor....
-
4.10.3 HALL CALL BUTTONS
Objects mounted beneath hall call buttons shall not project into the elevator lobby more than 4 in (100 mm)....
- Delta Single Handle Centerset Lavatory Faucet Less Pop-Up 511LF-HGMHDF
-
Section C: Exterior Route
(§302.1) C5 Is the route free of wall mounted objects that protrude more than 4" into the path of travel and are between 27" and 80" high?...
-
Issue 5: Tactile arrow (in line)
Since the tactile arrow is on the face of the device or on the pushbutton, the APS mounting affects arrow alignment....
-
1117B.1, Item 5
The bubbler shall be activated by a manually operated system complying with Section 1117B.6, Item 4 that is front mounted or side mounted and located within 6 inches (152mm) of the front...
-
1117B.1, Item 4
The bubbler shall be activated by a manually operated system complying with Section 1117B.6, Item 4 that is front mounted or side mounted and located within 6 inches (152mm) of the front...
-
Protruding Objects
Requirements: All objects that protrude from surfaces or posts and all overhanging objects in areas where people walk shall comply with the following requirements: Objects mounted...
-
11B-604.8.1.1 Size
60 inches (1524 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1422 mm) deep minimum for wall hung water closets and 59 inches (1499 mm) deep minimum for floor mounted...
- Takeform Fusion Signage Office/Suite/Room Identification Type G
- Takeform Fusion Signage Office/Suite/Room Identification Type F
- Takeform Fusion Signage Office/Suite/Room Identification Type G.2
-
A4.12.2 Window Hardware
Windows requiring pushing, pulling, or lifting to open (for example, double-hung, sliding, or casement and awning units without cranks) should require no more than 5 lbf (22.2 N) to open...
-
11B-403.6 Handrails
Handrails provided in elevator cabs and platform lifts are not required to comply with the requirements for handrails on walking surfaces....
-
11B-403.6 Handrails
Handrails provided in elevator cabs and platform lifts are not required to comply with the requirements for handrails on walking surfaces....
- Endorphin 325 Functional Wall Pulley
- Inpro Corporation JointMaster® 103 Series-VCT Expansion Joint Systems
- Inpro Corporation JointMaster® 101 Series Floor Expansion Joint Covers
-
3001.3 Accessibility
Passenger elevators and platform (wheelchair) lifts required to be accessible by Chapter 11A or 11B shall conform to Chapter 11A for applications listed in Section 108.2.1.2 regulated by...
-
R309.5.1 Location
Locating parking meters at the head or foot of the parking space permits deployment of a van side-lift or ramp or the vehicle occupant to transfer to a wheelchair or scooter....
-
Special Technical Provisions for Alterations to Existing Buildings and Facilities [4.1.6(3)]
Special provisions also address stairs, elevators, doors, toilet rooms, assembly areas, platform lifts, and dressing rooms....