transit boarding platforms shall comply with Figure 11B-705.2 and shall be 0.1 inch (2.5 mm) in height that tapers off to 0.04 inch (1.0 mm) , with bars raised 0.2 inch (5.1 mm) from the surface...
Search Results "Tread Surface"
Commonly Searched Documents
-
11B-705.2 Detectable directional texture
-
1133A.4.1 Repositionable countertops
Repositionable countertops shall comply with the following: Sinks and work surfaces required by Section 1133A.4 shall be designed to enable repositioning to a minimum height of 28...
-
3.2 Study Limitations and Other Issues
warning surface and the luminance contrast of the warning surface with adjacent surfaces....
-
Location and Size
The side rails are 20 inches minimum in length, 6 inches minimum in height above the table surface, and 1 inch measured horizontally from the adjacent edge of the table surface....
-
Boat Slips: ADA Standard Section 1003.2.1
Where handrail extensions are provided on gangways or transition plates, the handrail extensions shall not be required to be parallel with the ground or floor surface. 7....
-
11B-1003.2.1 Boat slips
The vertical distance is 10 feet (3050 mm) between the elevation where the gangway departs the landside connection and the elevation of the pier surface at the lowest water level....
-
Transfer Devices for Use with Amusement Rides: ADA Standard Section 1002.6
Where possible, designers are encouraged to locate the transfer device seat no higher than 17 to 19 inches 430 to 485 mm) above the load and unload surface....
-
11B-1002.6 Transfer devices for use with amusement rides
Where possible, designers are encouraged to locate the transfer device seat no higher than 17 to 19 inches (430 to 485 mm) above the load and unload surface....
-
Appendix D: Photometric Measurements
that would be reflected from a perfectly diffusely reflecting surface....
-
R208.1 Where Required
Detectable warning surfaces complying with R305 shall be provided at the following locations on pedestrian access routes and at transit stops: 1....
-
Clearance
Section 403.5 specifies a continuous clearance of 36 inches minimum for walking surfaces....
-
M307.2 Tactilely Discernible (Section-by-Section Analysis)
Patients who are blind or have low vision have difficulty distinguishing a flat membrane button or similar control unless it is tactilely discernible from the surrounding surface and any...
-
5.3.2.3 Slope
The slope of the turning space and clear floor or ground space surface shall not be steeper than 1:48 (2 percent) in all directions....
-
Finish and Contrast: ADA Standard Section 703.6.2
Additional factors affecting the ease with which the text can be distinguished from its background include shadows cast by lighting sources, surface glare, and the uniformity of the text...
-
Passing Spaces: ADA Standard Section 403.5.3
Section 403.5.3 covers the current ADA Standards for passing spaces that are part of an accessible route.
-
11B-703.7.2.7 Pedestrian traffic-control buttons
Control buttons shall be located no higher than 48 inches (1219 mm) above the ground surface adjacent to the pole....
-
Polypavement
After uncharacteristically heavy rainfall, the surface became the same texture as mud. Upon drying up, the surface remained cracked and was heaving along the full width of the trail....
-
904.3.2 Counter
The counter surface height shall be 38 inches (965 mm) maximum above the finish floor or ground....
-
4.34.6.4(1)
(1) The counter shall be mounted at a maximum height of 34 in (865 mm) above the floor, measured from the floor to the top of the counter surface, or shall be adjustable or replaceable as...
-
1132A.4 Level floor or landing
Primary entry doors, required exit doors or secondary exterior doors with changes in height between the interior surface or floor level and the exterior surface or floor level shall comply...
-
Seat Height
Commenters noted that this specification should be clarified as applying to the height as measured at the top of the seat surface. Response....
-
11B-904.3.2 Counter
The counter surface height shall be 38 inches (965 mm) maximum above the finish floor or ground....
-
R405.3.3 Minimum Required Depth
Where knee clearance is required under an element as part of a clear space, the knee clearance shall be 280 mm (11 in) deep minimum at 230 mm (9 in) above the finish surface, and 205 mm...
-
Illumination Levels (Reserved) [4.30.8]
A level from 10 to 30 footcandles is recommended uniformly over the sign surface....