(18) If fixed or built-in seating or tables (including, but not limited to, study carrels and student laboratory stations), are provided in accessible public or common use areas, at...
Search Results "Monitoring Space"
-
4.1.3(18)
-
4) Where the Standard is silent about changes in level
4) Where the Standard is silent about changes in level, such as 604.3 around a water closet or in a toilet compartment: Since there is no mention of the phrase "changes in level...
-
3.1.4.2 Width of RV Campsite and Dump Station Vehicle Parking Areas
Where RV camping units or dump stations are provided, vehicle parking areas for recreational vehicles and trailers that are required to be accessible in accordance with table 3.1.1...
-
M303.3.3.5 Handrails
Ramps with a rise greater than 6 inches (150 mm) shall provide handrails on each side.
-
M303.3.3.3 Clear Width
The clear width of ramp runs shall be 36 inches (915 mm) minimum.
-
M303.3.3.1 Running Slope
Ramp runs shall have a running slope not steeper than 1:12.
-
11B-228.3 Electric vehicle charging stations
[See subsections ...]
-
11B-228.3 Electric vehicle charging stations
[See subsections ...]
-
11B-813.2.1.2 Clearance
A 36 inches minimum (914 mm) width side clearance shall be provided along the entire length of one side of adult changing tables. At both ends of adult changing tables, clearance...
-
Rooms and Spaces: ADA Standard Section 206.5.2
Section 206.5.2 covers scoping requirements in the most current ADA Standards for accessible routes to rooms and spaces.
-
Section 36.406(f) Assembly Areas (Section-by-Section Analysis)
Both designs have the potential to reduce the number of available wheelchair seating spaces below the level required. ...
- Access Board: Tactile Sign Braille Requirements
-
Surface [1017.2]
The surfaces of trails, passing spaces, and resting intervals must be firm and stable. A firm trail surface resists deformation by indentations....
-
General: ADA Standard Section 208.3.1
Section 208.3.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for parking space locations.
-
Water Hydrants and Water Spouts [1011.2, 1011.3, and 1011.6]
At water hydrants, a minimum of 72 by 48 inches of clear ground space must be provided with the long side of the space adjoining or overlapping an ORAR or trail as applicable, or another...
- Access Board: Informational and Directional Sign Requirements
-
30.1 Q. Would it be acceptable to use removable base cabinets beneath a wall-hung lavatory where a parallel approach is not possible?
The space under and around the cabinet should be finished prior to installation. For example, the tile or other floor finish must extend under the removable base cabinet....
-
Attachment E
Two of these spaces have no signs designating them as accessible. The accessible space in front has a sign that can be obscured by a parked vehicle. ...
-
ADA Business Brief - Restriping Parking Lots
[See subsections ...]
-
Features of an Accessible Examination Room
A clear floor space, 30” X 48” minimum, adjacent to the exam table and adjoining accessible route make it possible to do a side transfer. 2....
-
Built-Up Curb Ramps
Built-up curb ramps are permitted, but they cannot project in parking spaces, access aisles, or vehicle traffic lanes....