Sprinklers shall not be omitted from any room merely because it is damp, of fire-resistance-rated construction or contains electrical equipment....
Search Results "Fire Door"
Commonly Searched Documents
-
903.3.1.1.1 Exempt locations
-
1.1.5 Referenced codes
The National Fire Codes, standards, and the Fire Protection Handbook of the National Fire Protection Association are permitted to be used as authoritative guides in determining recognized...
-
Operable Parts: ADA Standard Section 804.6.2
Appliance doors and door latching devices shall not be required to comply with 309.4. 2....
-
711.3.3 Ducts and air transfer openings
Penetrations of fire-resistance-rated walls by ducts and air transfer openings that are not protected with fire dampers shall comply with this section....
-
11B-804.6.2 Operable parts
Exceptions: Appliance doors and door latching devices shall not be required to comply with Section 11B-309.4....
-
704.10 Vertical exposure
protectives shall be provided in every opening that is less than 15 feet (4572 mm) vertically above the roof of an adjoining building or adjacent structure that is within a horizontal fire...
-
4.3.11.1(3)
(3) A portion of a one-hour fire-resistive corridor (complying with local requirements for fire-resistive construction and for openings) located immediately adjacent to an exit enclosure...
-
Symbols: ADA Standard Section 407.4.7.1.3
Section 407.4.7.1.3 covers the current ADA Standards for the designation and indicator symbols on elevator car control buttons.
-
711.3.1 Through penetrations
Through penetrations of fire-resistance-rated walls shall comply with Section 711.3.1.1 or 711.3.1.2....
-
11B-407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3...
-
1.1.4 Appendices
with Health and Safety Code Section 18901 et. seq. for Building Standards Law, Health and Safety Code Section 17950 for State Housing Law and Health and Safety Code Section 13869.7 for Fire...
-
711.4.1 Through penetrations
Through penetrations of fire-resistance-rated horizontal assemblies shall comply with Section 711.4.1.1 or 711.4.1.2....
-
711.4.2 Membrane penetrations
Penetrations of membranes that are part of a fire-resistance-rated horizontal assembly shall comply with Section 711.4.1.1 or 711.4.1.2....
-
Vision Lights: ADA Standard Section 404.2.11
Section 404.2.11 covers the current ADA Standards for vision lights on manual doors and gates.
-
11B-809.10.5.4 Bathtub enclosures
Doors and panels of bathtub enclosures shall be constructed from approved, shatter-resistant materials. Hinged doors shall open outward....
-
704.8.2 First story
In occupancies other than Group H, unlimited unprotected openings are permitted in the first story of exterior walls facing a street that have a fire separation distance of greater than...
- Salsbury Industries Recessed Mounted Cell Phone Storage Locker 7 Door High Unit Master Keyed Locks
- Salsbury Industries Recessed Mounted Cell Phone Storage Locker 7 Door High Unit Resettable Combination Locks
-
11B-208.3.3.2
Attached private garages directly serving a single residential dwelling unit shall provide at least one of the following options: A door leading directly from the residential dwelling...
-
11B-411.4.7.3 Symbols
The control button for the emergency stop, alarm, door open, door close, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3....
- Lang Equipment Co. Heavy Duty Throw Latch & Keeper for Bathroom Stall Door
-
1009.8.1 System requirements
Two-way communication systems shall provide communication between each required location and the fire command center or a central control point location and a central control point is not...
-
11B-404.2.11 Vision lights
Doors, gates, and side lights adjacent to doors or gates, containing one or more glazing panels that permit viewing through the panels shall have the bottom of at least one glazed panel...