transfer supports on tables with transfer depths of less than or equal to 24 inches and positioning supports for transfer depths greater than 24 inches....
Search Results "Vertical Standing Support"
Commonly Searched Documents
-
5.4.1.2 Transfer and Positioning Support Location Recommendations for Imaging Equipment with Transfer Surfaces
-
407.12.2.1 Unobstructed Side Reach
Where the operable part is located 10 inches (255 mm) or less beyond the vertical reference plane, the operable part shall be 48 inches (1220 mm) high maximum and 15 inches (380 mm) high...
-
407.8.3 Forward Reach
The vertical reference plane shall be centered, and intersect with, the operable part....
-
407.12.3 Forward Reach
The vertical reference plane shall be centered, and intersect with, the operable part....
-
M304.1 General
Diagnostic equipment used by patients in a standing position shall comply with M304....
-
Head and Back Support (M301.3.3 and M302.3.3)
, prone, or side-lying position, and diagnostic equipment used by patients in a seated position can be adjusted to reclined positions, M301.3.3 and M302.3.3 would require head and back support...
-
406.4.1 Clear height
While the minimum height is required to be 7'-0" by this section, greater vertical clearance is required at van-accessible parking spaces, standard accessible parking spaces, the vehicular...
-
406.4.1 Clear height
While the minimum height is required to be 7'-0" by this section, greater vertical clearance is required at van-accessible parking spaces, standard accessible parking spaces, the vehicular...
-
M302.3.1 Transfer Supports (Section-by-Section Analysis)
transfer supports must comply with the technical requirements in M305.2 of the proposed rule....
- Installation Process of Genesis Vertical Platform Wheelchair Lift - Garaventa Lift
-
M302.3 Supports (Section-by-Section Analysis)
An editorial change was made to this section as a result of the change in M302.3.2, described below, to replace the word “stirrups” with the term “leg supports.”...
-
§ 38.125(b)(12) Use by standees
The lift may be marked to indicate a preferred standing position....
-
§ 38.159(b)(12) Use by standees
The platform may be marked to indicate a preferred standing position....
-
M301.3 Supports
Transfer supports, leg supports, and reclining surfaces shall comply with M301.3....
-
1017.9 Protruding Objects
However, entities should maintain the vertical clearance along the trail tread, resting intervals, and passing spaces free from tree branches for 80 inches high minimum above the ground....
-
ii. Accessible scales
Wheelchair scales are currently available as stand-alone devices or as equipment that is integrated into other medical equipment....
-
5.2 Counters and Bars
Where food or drink is served at counters exceeding 34 in (865 mm) in height for consumption by customers seated on stools or standing at the counter, a portion of the main counter which...
-
407.12.3 Forward Reach (Section-by-Section Analysis)
The proposed provision would also require the vertical reference plane to be centered on, and intersect with, the operable part....
-
4.4.3 Backrest and Armrest
structural strength of backs, armrests, and mounting devices shall comply with section 903.6 of the ABAAS, which states: “Allowable stresses shall not be exceeded for materials used when a vertical...
-
M301.3 Supports
Transfer supports, stirrups, and reclining surfaces shall comply with M301.3....
-
R402 Protruding Objects
R402 Protruding Objects
-
Head Room [4.3.5]
The 80 inch minimum vertical clearance applies not only to accessible routes but to all circulation routes (see 4.4.2)....
-
M302.3.2 Leg Supports (Section-by-Section Analysis)
The MDE NPRM did not propose to require stirrups to provide a method of supporting, positioning, and securing the patient’s legs for diagnostic equipment used by patients in the seated position...
- Garaventa Elvoron CPL Vertical Platform Lift