The length of transfer supports shall comply with M305.2.2.1 or M305.2.2.2.
Search Results "Treatment Chair"
Commonly Searched Documents
-
M305.2.2 Length
-
B. Information about the Aircraft
You should be familiar with and be able to provide information about aircraft accessibility for passengers with a disability when they request this information. [Secs. 382.21 and...
-
Pricilla Rogers, Ph.D., Center on Vision Loss, American Foundation for the Blind
Window treatments to reduce glare. Floor-to-ceiling windows have significant glare issues....
-
3. Ground and floor surface treatments
Ground and floor surface treatments 4.5 Accessible routes, and spaces, including floors, walks, ramps, stairs, and curb ramps....
-
D. Stowing and Treatment of Personal Equipment
You should be familiar with the legal requirements for storage and treatment of personal equipment used by passengers with a disability, including ventilator/respirators, non-spillable batteries...
-
5.3.1 Permitted Obstructions to Transfer Sides for M301 and M302
The provision will coincide with the seat area design of most examination chairs. NPRM Proposed Provision: M301.2.3 and M302.2.3 Transfer Sides....
-
36 CFR Part 1195 Proposed Accessibility Standards for Medical Diagnostic Equipment NPRM - Preamble
The proposed standards contain minimum technical criteria to ensure that medical diagnostic equipment, including examination tables, examination chairs, weight scales, mammography equipment...
-
M305.2.8 Fittings
Transfer supports shall not rotate within their fittings when in place for transfer.
-
M305.2.7 Clearance
Clearance between the transfer support gripping surface and adjacent surfaces or obstructions shall be 1 ½ inches (38 mm) minimum.
-
M305.2.7 Clearance (Section-by-Section Analysis)
In the MDE NPRM, the Access Board did not provide any specific requirements for clearances around the transfer support. However, in the preamble to the MDE NPRM the Access Board...
-
5.4.10 Transfer Support Fittings Recommendations for M301 and M302
5.4.10 Transfer Support Fittings Recommendations for M301 and M302 Description: To ensure safe and effective transfers, transfer supports must not rotate within their fittings...
-
5.4.10 Transfer Support Fittings for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.10 Transfer Support Fittings for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position. The transfer supports shall not rotate when locked in place for patient...
-
Attachment A: Disability-Related Issues for Emergency Plan Coordinators
(Give a copy of this checklist to personnel who are responsible for creating, reviewing, maintaining, practicing and revising emergency plans.) DISABILITY-RELATED ISSUES FOR...
-
M305.2.3 Fittings
Transfer supports shall not rotate within their fittings.
-
Table 2: Summary of Department of Transportation Survey
Architectural Research Consulting 20-07 (167) No. Element surveyed Minimum reported tolerance Maximum reported tolerance Average reported...
- Brewer Access™ High-Low Exam Table
- Midmark 623 Barrier-Free® Power Examination Table
- Midmark 625 Barrier-Free® Power Examination Table
- Midmark Ritter 222 Barrier-Free® Power Examination Table
- Midmark Ritter 223 Barrier-Free® Power Examination Table
-
M305.2.1 Location
Transfer supports shall comply with M305.2.1.1 or M305.2.1.2 and shall be located 1 ½ inches (38 mm) maximum measured horizontally from the plane defined by the nearest edge of the...
-
M305.2.4 Cross Section
Transfer supports shall have a cross section complying with 305.2.4.1 or 305.2.4.2.
-
M305.2.3 Height
During use, the tops of transfer support gripping surfaces shall be 6 inches (150 mm) minimum and 19 inches (485 mm) maximum higher than the top of the associated uncompressed...
-
M305.2.6 Gripping Surface
Transfer support gripping surfaces shall be continuous along their length and shall not be obstructed along their tops or sides. The bottoms of transfer support gripping surfaces...