The transfer surface shall be 21 inches (610 mm) wide minimum and 15 inches (381 mm) deep minimum. Advisory M302.2.2 Size....
Search Results "Transfer Surface"
-
M302.2.2 Size
-
Transfer Supports
Transfer Supports A means of support is required when transferring into the entry or seat of a play component....
-
How To Transfer from a Wheelchair to Hospital Bed (Stretcher) with a Sliding Board
Requires the Registered User plan or above. Login!
-
11B-406.5.4 Floor or ground surfaces
Floor or ground surfaces of curb ramps and blended transitions shall comply with Section 11B-405.4....
-
11B-406.5.4 Floor or ground surfaces
Floor or ground surfaces of curb ramps and blended transitions shall comply with Section 11B-405.4....
-
1. Transfer Surface
[See subsections ...]
-
11B-407.4.2 Floor surfaces
Floor surfaces in elevator cars shall comply with Section 11B-302 and 11B-303....
-
11B-407.4.2 Floor surfaces
Floor surfaces in elevator cars shall comply with Section 11B-302 and 11B-303....
-
5.2.1.4 Transfer Surface Size for Imaging Equipment
5.2.1.4 Transfer Surface Size for Imaging Equipment. The transfer surface should be 28 inches wide minimum and 21 inches deep minimum....
-
11B-1002.6.2 Transfer height
The height of transfer device seats shall be 14 inches (356 mm) minimum and 24 inches (610 mm) maximum measured from the load and unload surface....
-
11B-608.9 Shower floor or ground surface
Floor or ground surfaces of showers shall comply with Section 11B-302.1 and shall be sloped 1:48 maximum in any direction....
-
11B-608.9 Shower floor or ground surface
Floor or ground surfaces of showers shall comply with Section 11B-302.1 and shall be sloped 1:48 maximum in any direction....
-
Surfaces
An accessible surface is firm and stable. Use caution with the size and depth of gravel when maintaining unpaved surfaces....
-
Highest and Lowest Heights Obtained
These data represent the ability of the participants in the study to complete a transfer....
-
Dining Surfaces and Work Surfaces for Children's Use: ADA Standard Section 902.4
Accessible dining surfaces and work surfaces for children’s use shall comply with 902.4....
-
5.3.1 Permitted Obstructions to Transfer Sides for M301 and M302
provide options to transfer onto the short side and the long side of the surface....
-
Walking Surfaces: ADA Standard Section 403
Section 403 covers the current ADA Standards for walking surfaces that are part of an accessible route.
-
Transfer Demonstration from Wheelchair to Bed and Back to Wheelchair
Requires the Registered User plan or above. Login!
-
Floor or Ground Surfaces: ADA Standard Section 305.2
Section 305.2 covers the current ADA Standards for floor or ground surfaces of clear floor or ground space.
-
1008.3.2.3 Transfer Supports
1008.3.2.3 Transfer Supports. At least one means of support for transferring shall be provided. Advisory 1008.3.2.3 Transfer Supports....
-
1008.3.1.3 Transfer Space
1008.3.1.3 Transfer Space. A transfer space complying with 305.2 and 305.3 shall be provided adjacent to the transfer platform....
-
Study Objectives
The purpose of this study was to examine independent transfers to and from a WMD and a simple platform, with and without the use of grab bars and/or a backrest, and transfers between two...
-
M301.2.1 Height
The height of the transfer surface during patient transfer shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum measured from the floor to the top of the transfer surface....
-
11B-404.2.4.4 Floor or ground surface
Floor or ground surface within required maneuvering clearances shall comply with Section 11B-302....