Pre-shaped stair coverings consisting of stair nosing, riser and tread all in one piece for straight steps with right-angled edge. ...
Search Results "Trail Tread"
Commonly Searched Documents
- Nora Systems, Inc. Norament Grano Stairtreads
- Nora Systems, Inc. Norament Satura Stairtreads
-
Constructed Features
Constructed Features are commonly found along trails or as part of trails....
- Wetland Trail Design and Construction
-
Documenting Exceptions and Notifying the U.S. Access Board About Exemptions
the reason that full compliance wasn't achieved and file it with the project records for the trail construction or alteration project....
-
F201.4.1 Documentation and Notification When Exceptions Used for Trails and Beach Access Routes
Federal agencies shall document the basis for not fully complying with a specific provision in 1017 or 1018 on a portion of a trail or beach access route based on Exception 1 in 1017 or...
-
1017.7.1 Maximum Running Slope and Segment Length
Not more than 30 percent of the total length of a trail shall have a running slope steeper than 1:12 (8.33%)....
-
1017.7.1 Maximum Running Slope and Segment Length
Not more than 30 percent of the total length of a trail shall have a running slope steeper than 1:12 (8.33%)....
-
6.9 Tread Obstacles
Obstacles on beach access routes and their related resting intervals shall not exceed 1 inch (25 mm) in height measured vertically to the highest point. Where the surface is...
-
Summary of Costs and Benefits
We estimate the final rule would result in additional costs for viewing areas, trails, and beach access routes shown in Table 3....
-
1011.1 General
The requirements in 1011 apply to outdoor constructed features provided within camping facilities, picnic facilities, viewing areas, and trailheads or on trails....
-
Designed Use
The “Managed Use” of a trail that requires the most demanding design, construction, and maintenance parameters....
- Nora Systems, Inc. Norament 920 Stairtreads
-
F213.1 General
* * * * * EXCEPTION: Pit toilets provided on trails and in camping facilities shall not be required to comply with F213. Advisory F213.1 General....
-
7.2.2 General Exception 2
If after applying General Exception 1 it is determined that it is impracticable to provide a trail complying with 7.4, the trail shall not be required to comply with 7.4....
-
7.2.2.2 Extent of Impracticability
Where General Exception 2 permits exemption of an entire trail from the requirements of section 7.4.1 through 7.4.8, it may be beneficial to construct a portion of the trail to meet the...
-
Running Slope [1017.7.1]
Running slope, also referred to as grade, is the lengthwise slope of a trail, parallel to the direction of travel....
-
7.4.3.1 Running Slope (Grade)
Trail running slope (grade) of up to 1:20 (5 percent) is permitted for any distance....
-
F247.4.4 Routes
Routes that connect trails complying with 1017 to camping facilities, picnic facilities, viewing areas, pit toilets, and accessible elements provided within the facilities shall comply with...
-
Web Sites for Gate Designs and Suppliers in the United Kingdom
Scottish Natural Heritage http://www.snh.org.uk/publications/on-line/accessguide/gates.asp BTCV (British Trust for Conservation Volunteers)...
-
7.4.4.3 Slope
The slope of a resting interval shall not exceed 1:20 (5 percent) in any direction. Where the surface is paved or is elevated above the natural ground, the slope shall not be steeper...
- Figure 504.5 Stair Nosings – Drawing from the U.S. Access Board
-
Clear Tread Width and Passing Spaces for Outdoor Recreation Access Routes
Clear tread width means the width of the traveled surface on the ground and also above the ground between obstacles (figure 40)....
- American Safety Tread Co., Type G505R Stairway Nosing/Tread Replacement