Signs at elevator hoistways shall comply with 407.2.3.1.
Search Results "Substantially Limits"
Commonly Searched Documents
-
408.2.3 Hoistway Signs
-
408.4.6 Car Controls
Elevator car controls shall comply with 407.4.6. Control panels shall be centered on a side wall.
-
408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated.
-
408.2.2 Hall Signals
Hall signals shall comply with 407.2.2.
-
408.3.2.1 Power Operation
408.3.2.1 Power Operation. Swinging doors shall be power-operated and shall comply with ANSI/BHMA A156.19 (1997 or 2002 edition) (incorporated by reference, see "Referenced...
-
408.2.2 Hall Signals
408.2.2 Hall Signals. Hall signals shall comply with 407.2.2.
-
408.3.2.2 Duration
408.3.2.2 Duration. Power-operated swinging doors shall remain open for 20 seconds minimum when activated.
-
408.4.6 Car Controls
408.4.6 Car Controls. Elevator car controls shall comply with 407.4.6. Control panels shall be centered on a side wall.
-
408.2.3 Hoistway Signs
Signs at elevator hoistways shall comply with 407.2.3.1.
-
11B-408.3.2.1 Power operation
Swinging doors shall be power-operated and shall comply with ANSI/BHMA A156.19.
-
11B-408.4.6 Car controls
Elevator car controls shall comply with Section 11B-407.4.6. Control panels shall be centered on a side wall.
-
11B-408.2.2 Hall signals
Hall signals shall comply with Section 11B-407.2.2.
-
11B-408.2.3 Hoistway signs
Signs at elevator hoistways shall comply with Section 11B-407.2.3.1.
-
11B-408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated.
-
11B-408.2.2 Hall signals
Hall signals shall comply with Section 11B-407.2.2.
-
11B-408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated.
-
11B-408.2.3 Hoistway signs
Signs at elevator hoistways shall comply with Section 11B-407.2.3.1.
-
11B-408.3.2.1 Power operation
Swinging doors shall be power-operated and shall comply with ANSI/BHMA A156.19.
-
11B-408.4.6 Car controls
Elevator car controls shall comply with Section 11B-407.4.6. Control panels shall be centered on a side wall.
-
Permitted Protrusions in Wheelchair Spaces: ADA Standard Section 1002.4.4.3
Objects are permitted to protrude a distance of 6 inches (150 mm) maximum along the front of the wheelchair space, where located 9 inches (230 mm) minimum and 27 inches (685 mm)...
-
11B-1002.4.4.3 Permitted protrusions in wheelchair spaces
Objects are permitted to protrude a distance of 6 inches (152 mm) maximum along the front of the wheelchair space, where located 9 inches (229 mm) minimum and 27 inches (686 mm)...
-
11B-206.6 Elevators
Elevators provided for passengers shall comply with Section 11B-407. Where multiple elevators are provided, each elevator shall comply with Section 11B-407. Exceptions: In a...
-
4.1.6(3)(a)
(a) At least one accessible route complying with 4.3, Accessible Route, and 4.1.6(a);
-
F203.5 Limited Access Spaces
Spaces accessed only by ladders, catwalks, crawl spaces, or very narrow passageways shall not be required to comply with these requirements or to be on an accessible route.