Changes in level between ¼ inch (6.4 mm) high minimum and ½ inch (12.7 mm) high maximum shall be beveled with a slope not steeper than 1:2....
Search Results "Substantial Proposed Change"
-
11B-303.3 Beveled
-
36 CFR Part 1195 Proposed Accessibility Standards for Medical Diagnostic Equipment NPRM
ACTION: Notice of Proposed Rulemaking....
-
303.2 Vertical
Changes in level of ¼ inch (6.4 mm) high maximum shall be permitted to be vertical. Figure 303.2 Vertical Change in Level...
-
303.3 Beveled
Changes in level between 1/4 inch (6.4 mm) high minimum and 1/2 inch (13 mm) high maximum shall be beveled with a slope not steeper than 1:2. Advisory 303.3 Beveled....
-
303.2 Vertical
Changes in level of ¼ inch (6.4 mm) high maximum shall be permitted to be vertical. Figure 303.2 Vertical Change in Level...
-
11B-303.3 Beveled
A change in level of 1/2 inch (13 mm) is permitted to be 1/4 inch (6.4 mm) vertical plus 1/4 inch (6.4 mm) beveled....
-
11B-303.2 Vertical
Changes in level of ¼ inch (6.4 mm) high maximum shall be permitted to be vertical and without edge treatment. [2010 ADAS] 303.2 Vertical. ...
-
11B-303.2 Vertical
Changes in level of ¼ inch (6.4 mm) high maximum shall be permitted to be vertical and without edge treatment. [2010 ADA Standards] 303.2 Vertical....
-
Sections 35.108(d)(3) and 36.105(d)(3)—Condition, Manner, or Duration
substantially limit major life activities....
-
Baby Changing Table
-
Baby Changing Table
While in the toilet room, this mounting location is not much better.
-
11B-813.2 Features
Adult changing facilities shall provide features in compliance with Section 11B-813.2....
-
303.2 Vertical
Changes in level of 1/4 inch (6.4 mm) high maximum shall be permitted to be vertical....
-
Lines of Sight and Dispersion: ADA Standard Section 221.2.3
Section 221.2.3 covers scoping requirements in the current ADA Standards for lines of sight and dispersion of wheelchair spaces in assembly areas.
-
303.4 Ramps
Changes in level greater than ½ inch (13 mm) high shall be ramped, and shall comply with 405 or 406....
-
303.4 Ramps
Changes in level greater than ½ inch (13 mm) high shall be ramped, and shall comply with 405 or 406....
-
303.4 Ramps
Changes in level greater than 1/2 inch (13 mm) high shall be ramped, and shall comply with 405 or 406....
-
11B-221.2.3 Lines of sight and dispersion
Wheelchair spaces shall provide spectators with choices of seating locations and viewing angles that are substantially equivalent to, or better than, the choices of seating locations and...
-
11B-221.2.3 Lines of sight and dispersion
Wheelchair spaces shall provide spectators with choices of seating locations and viewing angles that are substantially equivalent to, or better than, the choices of seating locations and...
-
11B-303.4 Ramps
Changes in level greater than ½ inch (12.7 mm) high shall be ramped, and shall comply with Section 11B-405 or 11B-406....
-
11B-303.4 Ramps
Changes in level greater than ½ inch (12.7 mm) high shall be ramped, and shall comply with Section 11B-405 or 11B-406....
-
11B-303.4 Ramps
Changes in level greater than ½ inch (12.7 mm) high shall be ramped, and shall comply with Section 11B-405 or 11B-406....
-
36 CFR Part 1195 Proposed Accessibility Standards for Medical Diagnostic Equipment NPRM - Preamble
ACTION: Notice of Proposed Rulemaking....
-
§ 36.105(d)(2)(iii)
For example, applying these principles it should easily be concluded that the types of impairments set forth in paragraphs (d)(2)(iii)(A) through (K) of this section will, at a minimum, substantially...