During times that the building is occupied, in lieu of the automatic activation of alarm notification appliances, the manual fire alarm system shall be allowed to activate an alarm signal...
Search Results "Smoke Alarm"
-
907.2.7.1 Occupant notification
-
4.1.3(14)
(14) If emergency warning systems are provided, then they shall include both audible alarms and visual alarms complying with 4.28....
- Safety Technology: the First 30 Years
-
907.2.6.2.1 System initiation
Actuation of an automatic fire-extinguishing system, a manual fire alarm box or a fire detector shall initiate an approved fire alarm signal which automatically notifies staff....
-
907.2.8 Group R-1
A manual fire alarm system and an automatic fire detection system shall be installed in Group R-1 occupancies....
-
907.2.7 Group M
A manual fire alarm system shall be installed in Group M occupancies having an occupant load of 500 or more persons or more than 100 persons above or below the lowest level of exit discharge...
-
806.3.1 Alarms
806.3.1 Alarms. Where emergency warning systems are provided, alarms complying with 702 shall be provided....
-
4.3.11.1(7)
Such pressurization system shall be activated by smoke detectors on each floor located in a manner approved by the appropriate local authority....
-
4.28.3(7)
(7) In general, no place in any room or space required to have a visual signal appliance shall be more than 50 ft (15 m) from the signal (in the horizontal plane). In large rooms and...
-
4.28.3(6)
(6) The appliance shall be placed 80 in (2030 mm) above the highest floor level within the space or 6 in (152 mm) below the ceiling, whichever is lower.
-
702.1 General
Fire alarm systems shall have permanently installed audible and visible alarms complying with NFPA 72 (1999 or 2002 edition) (incorporated by reference, see "Referenced Standards" in Chapter...
-
702.1 General
Fire alarm systems shall have permanently installed audible and visible alarms complying with NFPA 72 (1999 or 2002 edition) (incorporated by reference, see "Referenced Standards" in Chapter...
-
702.1 General
Fire alarm systems shall have permanently installed audible and visible alarms complying with NFPA 72 (1999 or 2002 edition) (incorporated by reference, see "Referenced Standards" in Chapter...
-
1.1.3.2, Item 14.3
Fire alarm devices, equipment and systems in connection with any occupancy....
-
[F] 907.4.2.2 Height
The height of the manual fire alarm boxes shall be a minimum of 42 inches (1067 mm) and a maximum of 48 inches (1219 mm) measured vertically, from the floor level to the activating handle...
-
702 Fire Alarm Systems
702 Fire Alarm Systems...
-
907.2.6.2 Group I-3
Group I-3 occupancies shall be equipped with a manual and automatic fire alarm system installed for alerting staff....
-
Location: ADA Standard Section 407.4.6.4.2
Section 407.4.6.4.2 covers the current ADA Standards for the location of the emergency controls in elevator cars.
-
11B-407.4.6.4.2 Location
Emergency controls, including the emergency alarm, shall be grouped at the bottom of the panel....
-
11B-407.4.6.4.2 Location
Emergency controls, including the emergency alarm, shall be grouped at the bottom of the panel....
-
Location and Spacing
Provisions for the spacing of visual alarms in hallways and corridors generally require one fixture every 100 feet....
-
806.3.1 Alarms
Where emergency warning systems are provided, alarms complying with 702 shall be provided....
-
806.3.1 Alarms
Where emergency warning systems are provided, alarms complying with 702 shall be provided....
-
11B-215.4 Transient lodging
Guest rooms required to comply with Section 11B-224.4 shall provide fire alarms complying with Chapter 9, Section 907.5.2.3.3, and carbon monoxide alarms, where provided, complying with...