Section 407.4.7.2 covers the current ADA Standards for designations and indicators on elevator keypads.
Search Results "Raised Curb"
-
Keypads: ADA Standard Section 407.4.7.2
-
Diagonal Curb Ramps
Section 406.6 provides specifications for diagonal (or corner type) curb ramps. These curb ramps must have a 48 inch minimum clear space at the bottom....
-
Areas Raised for Security/ Safety (§203.3)
Areas Raised for Security/ Safety (§203.3) Areas raised primarily for purposes of security or life/ fire safety Examples: life guard stands, fire towers, and prison guard towers...
-
Sides of Curb Ramps
However, curbs with returned sides remain an alternative to flared sides....
-
R304.1 General
There are two types of curb ramps: • Perpendicular curb ramps have a running slope that cuts through or is built up to the curb at right angles or meets the gutter break at right angles...
-
10 [§ 4.7.5]
10 [§ 4.7.5] Answer this question only if you skipped the previous two questions because the curb ramp you are surveying does not have flared sides....
-
11B-705.1.2.2.2 Parallel curb ramps
Detectable warnings at parallel curb ramps shall be located so the edge nearest the curb is 6 inches (152 mm) minimum and 8 inches (203 mm) maximum from the demarcation line at the face...
-
C. Raised Porches Are Part Of the Store That Must Be Made Accessible and Located On An Accessible Route
The four exemptions addressing raised spaces are inapplicable here: “Raised Areas. ...
-
B7. Curb Ramp Width
Is the width of the curb ramp surface at least 36 inches? [ADA Stds 4.7.3] Yes _____ No _____...
-
11B-705.1.2.2.1 Perpendicular curb ramps
Detectable warnings at perpendicular curb ramps shall extend 36 inches (914 mm) in the direction of travel....
-
B6. Curb Ramp Slope
If a curb ramp is provided, is the slope of the ramp surface (not counting the side flares) no more than 1:12? [ADA Stds 4.7.2] Yes _____ No _____...
-
4.7.11 Islands
Any raised islands in crossings shall be cut through level with the street or have curb ramps at both sides and a level area at least 48 in (1220 mm) long between the curb ramps in the part...
-
Type: ADA Standard Section 407.4.7.1.1
Section 407.4.7.1.1 covers the current ADA Standards for type of designations and indicators required on elevator car control button.
-
Stroke Thickness: ADA Standard Section 703.2.6
Stroke thickness of the uppercase letter “I” shall be 15 percent maximum of the height of the character.
-
11B-703.2.6 Stroke thickness
Stroke thickness of the uppercase letter “I” shall be 15 percent maximum of the height of the character.
-
11B-407.4.6.2 Buttons
Car control buttons with floor designations shall comply with Section 11B-407.4.6.2. Exception: Reserved. [2010 ADA Standards] EXCEPTION: In existing elevators, buttons shall...
-
11B-407.4.6.2 Buttons
Car control buttons with floor designations shall comply with Section 11B-407.4.6.2. Exception: Reserved. [2010 ADA Standards] EXCEPTION: In existing elevators, buttons shall...
-
11B-703.2.6 Stroke thickness
Stroke thickness of the uppercase letter “I” shall be 15 percent maximum of the height of the character.
-
Section 35.151(i) Curb Ramps (Section-by-Section Analysis)
The current § 35.151(e) on curb ramps has been redesignated as § 35.151(i). ...
-
11B-407.4.7.2 Keypads
The number five key shall have a single raised dot. The dot shall be 0.118 inch (3 mm) to 0.120 inch (3.05 mm) base diameter and in other aspects comply with Table 11B-703.3.1....
-
11B-407.4.7.2 Keypads
The number five key shall have a single raised dot. The dot shall be 0.118 inch (3 mm) to 0.120 inch (3.05 mm) base diameter and in other aspects comply with Table 11B-703.3.1....
-
Section 35.151(i) Curb ramps (Section-by-Section Analysis)
Section 35.151(i) Curb ramps (Section-by-Section Analysis) Section 35.151(e) on curb ramps in the 1991 rule has been redesignated as § 35.151(i)....
-
R304 Curb Ramps and Blended Transitions (Section-by-Section Analysis)
R304 Curb Ramps and Blended Transitions (Section-by-Section Analysis)...