Proposed Guidelines Developed Specifically for Pedestrian Facilities in the Public Right-of-Way The proposed guidelines are developed specifically for pedestrian facilities in the public...
Search Results "Pedestrian Traffic Control Button"
Commonly Searched Documents
- 
    
  
  Proposed Guidelines Developed Specifically for Pedestrian Facilities in the Public Right-of-Way
  
- 
    
  
  11B-602.9 Pedestrian protection
  All drinking fountains shall either be located completely within alcoves, positioned completely between wing walls, or otherwise positioned so as not to encroach into pedestrian ways.... 
- 
    
  
  11B-602.9 Pedestrian protection
  All drinking fountains shall either be located completely within alcoves, positioned completely between wing walls, or otherwise positioned so as not to encroach into pedestrian ways.... 
- 
    
  
  11B-407.4.6.2.1 Size and shape
  Buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in their smallest dimension and be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding surface... 
- 
    
  
  11B-411.4.6 Elevator car controls
  Where provided, elevator car controls shall comply with Sections 11B-411.4.6 and 11B-309.4.... 
- 
    
  
  11B-411.2.1.4.1.1 Arrangement
  Buttons shall be arranged in columns to the right of the keypad with a minimum horizontal spacing of 1.5 times the horizontal spacing between the numeric keys and with the same vertical... 
- 
    
  
  11B-411.2.1.2.5 Audio output
  Upon activation of the accessibility function button, the audio output shall provide verbal announcements, including but not limited to, operating instructions, user input confirmation,... 
- 
    
  
  11B-703.7.2.3 Volume control telephones
  Telephones with a volume control shall be identified by a pictogram of a telephone handset with radiating sound waves on a square field such as shown in Figure 11B-703.7.2.3.... 
- 
    
  
  Visible Indicators: ADA Standard Section 407.4.7.1.4
  Section 407.4.7.1.4 covers the current ADA Standards for visible indicators on elevator car control buttons. 
- 
    
  
  R302.5 Grade
  Except as provided in R302.5.1, where pedestrian access routes are contained within a street or highway right-of-way, the grade of pedestrian access routes shall not exceed the general grade... 
- 
    
  
  Verify Electrical
  Measure to top or bottom of boxes 11B-308.1.2 Alarm/detector systems. 11B-702 Height of HVAC controls.... 
- 
    
  
  Verify Electrical
  Measure to top or bottom of boxes 11B-308.1.2 Alarm/detector systems. 11B-702 Height of HVAC controls.... 
- 
    
  
  Question 22
  Are there any obstacles that block access to lift or elevator controls? Obstacles may include trash receptacles or cigarette urns.... 
- 
    
  
  Elevator Car Controls
  Comments recommended that the height of elevator car controls be harmonized with the ANSI A117.1 standard.... 
- Figure 406.6 Diagonal or Corner Type Curb Ramps – Drawing from the U.S. Access Board
- Viking E-1600-IP VoIP Emergency Phones with Built-in Auto Dialer and Digital Announcer
- 
    
  
  Design of Shared Use Paths, Street Intersections, and Midblock Crossings
  , Guide to the Development of Bicycle Facilities and the upcoming Pedestrian Facilities Design Guide) and FHWA's Manual on Uniform Traffic Control Devices (MUTCD), and/or the creation of... 
- Viking E-1600A-BLT-EWP Emergency Tower Phone with Blue LED Beacon and Strobe Light
- Viking E-1600A-BLT2EWP Emergency Tower Phone with Blue Strobe Light, Voice Announcer and Weather Protection
- 
    
  
  What if a locality is not resurfacing an entire block, but is resurfacing a crosswalk by itself?
  Crosswalks constitute distinct elements of the right-of-way intended to facilitate pedestrian traffic.... 
- 
    
  
  11B-407.2.1.2 Size and shape
  Call buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in the smallest dimension and shall be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding... 
- 
    
  
  11B-407.2.1.2 Size and shape
  Call buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in the smallest dimension and shall be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding... 
- 
    
  
  11B-407.2.1.2 Size and shape
  The buttons shall be activated by a mechanical motion that is detectable. [2010 ADA Standards] 407.2.1.2 Size.... 
- 
    
  
  Volume Controls: ADA Standard Section 217.3
  Section 217.3 covers scoping requirements in the current ADA Standards for telephone volume controls. 