Outdoor recreation access routes required by F245.4.2 and F245.4.3 shall coincide with or be located in the same area as general circulation paths. Advisory F245.4.4 Location. ...
Search Results "Path"
Commonly Searched Documents
-
F245.4.4 Location
-
Alterations: ADA Standard Section 202.3
Section 202.3 covers the most current requirements for alterations in existing building and facilities.
-
Sec.36.403 Alterations: Path of travel
Sec.36.403 Alterations: Path of travel....
- Figure 810.10 (Exception) Track Crossings – Drawing from the U.S. Access Board
- Figure 307.2 Limits of Protruding Objects – Drawing from the U.S. Access Board
-
Exception 8
If an area has been altered without providing an accessible path of travel to that area, and subsequent alterations of that area or a different area on the same path of travel are undertaken...
-
11B-204.1 General
Protruding objects on circulation paths shall comply with Section 11B-307....
-
11B-307.3 Post-mounted objects
Free-standing objects mounted on posts or pylons shall overhang circulation paths 12 inches (305 mm) maximum when located 27 inches (686 mm) minimum and 80 inches (2032 mm) maximum above...
-
307.3 Post-Mounted Objects
Free-standing objects mounted on posts or pylons shall overhang circulation paths 12 inches (305 mm) maximum when located 27 inches (685 mm) minimum and 80 inches (2030 mm) maximum above...
-
11B-307.3 Post-mounted objects
Free-standing objects mounted on posts or pylons shall overhang circulation paths 12 inches (305 mm) maximum when located 27 inches (686 mm) minimum and 80 inches (2032 mm) maximum above...
-
11B-307.3 Post-mounted objects
Free-standing objects mounted on posts or pylons shall overhang circulation paths 12 inches (305 mm) maximum when located 27 inches (686 mm) minimum and 80 inches (2032 mm) maximum above...
-
307.3 Post-Mounted Objects
Free-standing objects mounted on posts or pylons shall overhang circulation paths 12 inches (305 mm) maximum when located 27 inches (685 mm) minimum and 80 inches (2030 mm) maximum above...
-
307.3 Post-Mounted Objects
Free-standing objects mounted on posts or pylons shall overhang circulation paths 12 inches (305 mm) maximum when located 27 inches (685 mm) minimum and 80 inches (2030 mm) maximum above...
-
Vertical Clearance [§307.4]
Vertical Clearance [§307.4] Headroom clearance of at least 80” high is required along all circulation paths (except at doors and doorways where a 78” minimum clearance is permitted to...
-
R302.5 Grade
The grade requirements in R302.5 apply to sidewalks and other pedestrian circulation paths, pedestrian street crossings and at-grade rail crossings, and pedestrian overpasses and underpasses...
-
Performance Areas
Performance Areas An accessible route must connect stages and other performance areas directly to seating areas where they are directly connected by a circulation path as well as to...
-
Accessible routes
Accessible routes that coincide with, or are located in the same area, as general circulation paths and elements such as ramps, elevators, and fare vending and collection must be placed...
-
§ 36.304(d)(1)
The path of travel requirements of §36.403 shall not apply to measures taken solely to comply with the barrier removal requirements of this section....
-
Sec.36.304(d)(1)
The path of travel requirements of Sec.36.403 shall not apply to measures taken solely to comply with the barrier removal requirements of this section....
-
F245.4.4 Location
Outdoor recreation access routes required by F245.4.2 and F245.4.3 shall coincide with or be located in the same area as general circulation paths. Advisory F245.4.4 Location....
-
A4.4.1 GENERAL
Since proper cane and guide dog techniques keep people away from the edge of a path or from walks, a slight overhang of no more than 4 in (100 mm) is not hazardous....
-
A4.4.1 General
Since proper cane and service animal techniques keep people away from the edge of a path or from walls, a slight overhang of no more than 4 in (100 mm) is not hazardous....
- Beneficial Designs The Universal Trail Assessment Process (UTAP)
-
207.1 General
Where means of egress are permitted by local building or life safety codes to share a common path of egress travel, accessible means of egress shall be permitted to share a common path of...