SECTION 1009 STAIRWAYS [DSA-AC] In addition to the requirements of this section, means of egress, which provide access to, or egress from, buildings or facilities where accessibility...
Search Results "Means of Egress"
-
SECTION 1009 STAIRWAYS
-
1009.7 Stair treads and risers
1009.7 Stair treads and risers. ...
-
1009.7.2 Riser height and tread depth
1009.7.2 Riser height and tread depth. ... Exceptions: 6. See Section 3404.1 for the replacement of existing stairways. [DSA-AC] For applications listed in Section 1.9.1...
-
1009.15 Handrails
1009.15 Handrails. ... [DSA-AC] For applications listed in Section 1.9.1 regulated by the Division of the State Architect-Access Compliance, see Chapter 11B, Sections 11B-504.6...
-
SECTION 1010 RAMPS
SECTION 1010 RAMPS [DSA-AC] In addition to the requirements of this section, means of egress, which provide access to, or egress from, buildings or facilities where accessibility is...
-
SECTION 1011 EXIT SIGNS
SECTION 1011 EXIT SIGNS
-
1011.4 Raised character and Braille exit signs
1011.4 Raised character and Braille exit signs. Tactile exit signs shall be required at the following locations:
-
1011.4, Item 1
1. Each grade-level exterior exit door that is required to comply with Section 1011.1 shall be identified by a tactile exit sign with the word, “EXIT.”
-
1011.4, Item 2
Each exit door that is required to comply with Section 1011.1, and that leads directly to a grade-level exterior exit by means of a stairway or ramp shall be identified by a tactile exit...
-
1011.4, Item 2.1
2.1 “EXIT STAIR DOWN”
-
1011.4, Item 2.2
2.2 “EXIT RAMP DOWN”
-
1011.4, Item 2.3
2.3 “EXIT STAIR UP”
-
1011.4, Item 2.4
2.4 “EXIT RAMP UP”
-
1011.4, Item 3
Each exit door that is required to comply with Section 1011.1, and that leads directly to a grade-level exterior exit by means of an exit enclosure or an exit passageway shall be identified...
-
1011.4, Item 4
4. Each exit access door from an interior room or area to a corridor or hallway that is required to comply with Section 1011.1, shall be identified by a tactile exit sign with the...
-
1011.4, Item 5
5. Each exit door through a horizontal exit that is required to comply with Section 1011.1 shall be identified by a sign with the words, “TO EXIT.”
-
Raised character and Braille exit signs
Raised character and Braille exit signs shall comply with Chapter 11A, Section 1143A or Chapter 11B, Sections 11B-703.1, 11B-703.2, 11B-703.3 and 11B-703.5. ETA Editor's Note...
-
SECTION 1012 HANDRAILS
SECTION 1012 HANDRAILS [DSA-AC] In addition to the requirements of this section, means of egress, which provide access to, or egress from, buildings or facilities where accessibility...
-
1013.2 Where required
1013.2 Where required. Guards shall be located along open-sided walking surfaces, including mezzanines, equipment platforms, stairs, ramps and landings that are located more than 30...
-
1013.2.1 Glazing
1013.2.1 Glazing. Where glass is used to provide a guard or as a portion of the guard system, the guard shall also comply with Section 2407. Where the glazing provided does not meet...
-
1013.3 Height
1013.3 Height. Required guards shall not be less than 42 inches (1067 mm) high, measured vertically as follows: 1. From the adjacent walking surfaces; 2. On stairs,...
-
SECTION 1017 AISLES
SECTION 1017 AISLES [DSA-AC] In addition to the requirements of this section, means of egress, which provide access to, or egress from, buildings or facilities where accessibility is...
-
1017.2 Aisles in assembly spaces
1017.2 Aisles in assembly spaces. Aisles and aisle accessways serving a room or space used for assembly purposes shall comply with Section 1028.
-
1017.3 Aisles in Groups B and M
1017.3 Aisles in Groups B and M. In Group B and M occupancies, the minimum clear aisle width shall be determined by Section 1005.1 for the occupant load served, but shall not be...