Handrails shall be continuous within the full length of each stair flight or ramp run....
Search Results "Hose Length"
Commonly Searched Documents
-
11B-505.3 Continuity
-
11B-403.7 Continuous gradient
All walks with continuous gradients shall have resting areas, 60 inches (1524 mm) in length, at intervals of 400 feet (121,920 mm) maximum....
-
1133A.4 Countertops
Kitchen countertops shall comply with this section and shall be provided with the following: A minimum linear length of 30 inches (762 mm) of countertop shall be provided for the kitchen...
-
11B-405.7.2.1
Where the ramp width is less than the top landing width additional landing length may be necessary to accommodate handrail extensions required to be in the direction of the ramp run without...
-
§ 38.29(f)
(f) For vehicles in excess of 22 feet in length, the minimum interior height along the path from the lift to the securement location shall be 68 inches....
- Inpro Corporation JointMaster® 925 Fire Barrier System Expansion Joint Systems
-
Vertical Alignment-Crest Vertical Curves
distance greater than length of vertical curve (S>L) Case 2-Sight distance less than lenght of vertical curve (S>L) For both equations, L = length of vertical curve...
-
M301.3 Transfer Supports
* Other Transfer Support Dimensions: (*not included in the Proposed Rule) • Sub-committee Recommendation: Length - At least 15 inches (300 mm) in length and located on the length...
-
Handrails Along Walking Surfaces [§403.6, §505]
Gripping surface must be continuous the full length and top and sides cannot be obstructed....
-
11B-809.10.7.3 Reinforcement for grab bars
The backing shall 40 (sic) inches (1016 mm) minimum in length....
-
11B-405.7.5 Doorways
Where a door swings onto a ramp landing width, additional ramp landing length as specified may be necessary to accommodate a clear level area for the wheelchair user to clear the door swing...
-
1132A.5.1 General
The floor or landing on the dwelling unit side of the primary entry door and any required exit door shall have a minimum length of not less than 44 inches (1118 mm)....
-
1132A.5.1 General
The floor or landing on the dwelling unit side of the primary entry door and any required exit door shall have a minimum length of not less than 44 inches (1118 mm)....
-
Accessible Routes: ADA Standard Section 1005.1
Where the total length of the gangway or series of gangways serving as part of a required accessible route is 30 feet (9145 mm) minimum, gangways shall not be required to comply with 405.2...
-
11B-1005.1 Accessible routes
Where the total length of the gangway or series of gangways serving as part of a required accessible route is 30 feet (9144 mm) minimum, gangways shall not be required to comply with Section...
-
11B-809.10.7.2 Location
The centerline of the water closet shall be 17 inches (432 mm) minimum to 18 inches (457 mm) maximum from a wall or partition that is 54 inches (1372 mm) minimum in length....
-
Americans with Disabilities Act: Assistance at Self-Serve Gas Stations
Americans with Disabilities Act: Assistance at Self-Serve Gas Stations People with disabilities may find it difficult or impossible to use the controls, hose, or nozzle of a self-serve...
-
5.9.2.1 Standing Supports on Single Ramped Entry Raised Platforms with Wheelchair Spaces
Standing supports should be located on both sides of platforms, a minimum of 34 inches between supports, integrated into the platform, and 32 inches minimum length (at least 80% of the platform...
-
407.12.1.1 Vertical Plane for Side Reach (Section-by-Section Analysis)
407.12.1.1 Vertical Plane for Side Reach (Section-by-Section Analysis) This section proposes that, where a side approach is provided, the vertical reference plane must have a minimum length...
-
Minimum Rear Wall Required.
It appears that this comment references the 2010 ADA Standards for Accessible Design for minimum bench length (42") but uses the CA - 2013 minimum bench length (48") to develop the minimum...
-
1132A.5.1 General
The floor or landing on the dwelling unit side of the primary entry door and any required exit door shall have a minimum length of not less than 44 inches (1118 mm)....
-
Parallel Approach: ADA Standard Section 904.4.1
A clear floor or ground space complying with 305 shall be positioned for a parallel approach adjacent to the 36 inch (915 mm) minimum length of counter. , EXCEPTION: Where the provided...
-
11B-405.9.2 Curb or barrier
To prevent wheel entrapment, the curb or barrier shall provide a continuous and uninterrupted barrier along the length of the ramp....
-
Recommendations
Recommendations Based on the data in Table 1 and the observations above, we recommend: a minimum flat surface of 40 in. length for platforms accommodating wheeled mobility devices...