The top of handrail gripping surfaces shall be 20 inches (508 mm) minimum and 28 inches (711 mm) maximum above the ramp surface.
Search Results "Height Adjustable"
Commonly Searched Documents
-
11B-1008.2.5.3.2 Handrail height
-
11B-605.2 Height and depth
Urinals shall be the stall-type or the wall-hung type with the rim 17 inches (432 mm) maximum above the finish floor or ground. Urinals shall be 13½ inches (343 mm) deep minimum...
-
Transfer Supports Location and Configuration M301.3 and M302.3
We recommended height adjustability of the transfer support but did not mandate it to give manufactures design options....
-
Raised Characters
Specifications for raised characters in section 703.2 address the depth, case, style or font type, character proportion and height, stroke thickness, and character and line spacing....
-
11B-703.5.5 Character height
Minimum character height shall comply with Table 11B-703.5.5....
-
11B-703.4.1 Height above finish floor or ground
[2010 ADA Standards] 703.4.1 Height Above Finish Floor or Ground....
-
505.4 Height
Handrails shall be at a consistent height above walking surfaces, stair nosings, and ramp surfaces....
-
M305.2.3 Height
During use, the tops of transfer support gripping surfaces shall be 6 inches (150 mm) minimum and 19 inches (485 mm) maximum higher than the top of the associated uncompressed...
-
11B-411.2.1.2.4.2 Size
Elevator assignment characters shall be 1 inch high (25 mm) minimum.
- Figure 904.3.2 Check-Out Aisle Counters – Drawing from the U.S. Access Board
-
A4.32.4 Height of Tables or Counters
A4.32.4 Height of Tables or Counters. Different types of work require different table or counter heights for comfort and optimal performance....
-
Line Spacing: ADA Standard Section 703.2.8
Spacing between the baselines of separate lines of raised characters within a message shall be 135 percent minimum and 170 percent maximum of the raised character height....
-
11B-703.2.8 Line spacing
Spacing between the baselines of separate lines of raised characters within a message shall be 135 percent minimum and 170 percent maximum of the raised character height....
-
11B-604.4 Seats
The seat height of a water closet above the finish floor shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum measured to the top of the seat....
-
A4.32.4 HEIGHT OF WORK SURFACES
Heavy manual work such as rolling dough requires a work surface height about 10 in (255 mm) below elbow height for a standing person....
-
In a doctor’s office or clinic with multiple exam rooms, must every examination room have an accessible exam table and sufficient clear floor space next to the exam table?
Q In a doctor’s office or clinic with multiple exam rooms, must every examination room have an accessible exam table and sufficient clear floor space next to the exam...
-
I have an accessible exam table, but if it is in use when a patient with a disability comes in for an appointment, is it OK to make the patient wait for the room to open up, or else use an exam table that is not accessible?
Q I have an accessible exam table, but if it is in use when a patient with a disability comes in for an appointment, is it OK to make the patient wait for the room to open up, or...
-
PART 3: ACCESSIBLE EXAMINATION ROOMS
An accessible examination room has features that make it possible for patients with mobility disabilities, including those who use wheelchairs, to receive appropriate medical care....
-
5.1.5 Floor Height
Where the floor at the entrance to the camp shelter is elevated above the ground surface, the floor shall be 17 (430 mm) high minimum to 19 inches (485 mm) high maximum measured from...
-
4.19.2 Height and Clearances
Lavatories shall be mounted with the rim or counter surface no higher than 34 in (865 mm) above the finish floor. Provide a clearance of at least 29 in (735 mm) above the finish...
-
4.19.2 HEIGHT AND CLEARANCES
Lavatories shall be mounted with the rim or counter surface no higher than 34 in (865 mm) above the finished floor. Provide a clearance of at least 29 in (735 mm) from the floor to...
-
602.4 Spout Height
602.4 Spout Height. Spout outlets shall be 36 inches (915 mm) maximum above the finish floor or ground....
-
The Brewer Company, LLC
for adjustable height transfer surfaces....
-
Exception 8
When the adjusted construction cost is less than or equal to the current valuation threshold, as defined in Chapter 2, Section 202, the cost of compliance with Section 11B-202.4 shall be...