Size and Spacing of Grab Bars and Handrails [4.26.2] Use of a grab bar or handrail requires the formation of a power grip so that thumb and fingers can be opposed and the surface of the...
Search Results "Handrail Height"
Commonly Searched Documents
-
Size and Spacing of Grab Bars and Handrails [4.26.2]
-
11B-703.8.9 Height above floor
Heights of low resolution variable message sign characters shall comply with Table 11B-703.8.4, based on the size of the characters on the sign....
-
Handrail Extensions
Handrail Extensions ADAAG addresses handrail height, diameter, and extensions provided to the end of the gangway....
-
Handrail Extensions
Handrail Extensions ADAAG addresses handrail height, diameter, and extensions provided to the end of the gangway....
-
Sections 505.10.2 and 505.10.3
Sections 505.10.2 and 505.10.3 of the 2010 Standards require handrail extensions at both the top and bottom of a flight of stairs....
-
Stairs
Error/Omission: Handrail extensions are not provided at the top and bottom risers....
-
4.9.4(2)
(2) If handrails are not continuous, they shall extend at least 12 in (305 mm) beyond the top riser and at least 12 in (305 mm) plus the width of one tread beyond the bottom riser....
-
1012.2 Height
Exceptions: For occupancies in Group R-3, and within individual dwelling units in occupancies in Group R-2, both as applicable in Section 101.2, guards whose top rail also serves as a handrail...
-
Handrails, Grab Bars, and Tub and Shower Seats [4.26]
Handrails, Grab Bars, and Tub and Shower Seats [4.26] ADAAG 4.26 provides technical requirements for: handrails at ramps [4.8] and stairs [4.9] grab bars at water closets...
-
Section 4.9.4
• Section 4.9.4 of the 1991 Standards requires handrails at the bottom of stairs to continue to slope for a distance of the width of one tread beyond the bottom riser nosing and to further...
-
R409.10.1 Top and Bottom Extension at Ramps
Ramp handrails shall extend horizontally above the landing for 305 mm (1.0 ft) minimum beyond the top and bottom of ramp runs....
-
R409.10.3 Bottom Extension at Stairways
At the bottom of a stair flight, handrails shall extend at the slope of the stair flight for a horizontal distance at least equal to one tread depth beyond the last riser nosing....
-
R409.10.2 Top Extension at Stairways
At the top of a stair flight, handrails shall extend horizontally above the landing for 305 mm (1.0 ft) minimum beginning directly above the first riser nosing....
-
505.8 Surfaces
Handrail gripping surfaces and any surfaces adjacent to them shall be free of sharp or abrasive elements and shall have rounded edges....
-
505.8 Surfaces
Handrail gripping surfaces and any surfaces adjacent to them shall be free of sharp or abrasive elements and shall have rounded edges....
-
11B-505.8 Surfaces
Handrail gripping surfaces and any surfaces adjacent to them shall be free of sharp or abrasive elements and shall have rounded edges....
-
505.8 Surfaces
Handrail gripping surfaces and any surfaces adjacent to them shall be free of sharp or abrasive elements and shall have rounded edges....
-
11B-505.8 Surfaces
Handrail gripping surfaces and any surfaces adjacent to them shall be free of sharp or abrasive elements and shall have rounded edges....
-
11B-505.8 Surfaces
Handrail gripping surfaces and any surfaces adjacent to them shall be free of sharp or abrasive elements and shall have rounded edges....
-
505.8 Surfaces
Handrail gripping surfaces and any surfaces adjacent to them shall be free of sharp or abrasive elements and shall have rounded edges....
-
505.1 General
Handrails provided along walking surfaces complying with 403, required at ramps complying with 405, and required at stairs complying with 504 shall comply with 505....
-
11B-411.4.11.1 Height
Floor destination characters shall be 1 inch (25 mm) high minimum complying with Section 11B-703.5.3.
-
4.9.4(7)
(7) Handrails shall not rotate within their fittings....
-
4.8.5(7)
(7) Handrails shall not rotate within their fittings....