Search Results "Handrail Clearance"
Commonly Searched Documents
- Figure 1009.3.3 Handrails for Sloped Entry – Drawing from the U.S. Access Board
-
Can handrail extensions wrap or turn?
Extensions are not required for continuous handrails along switchback or dogleg ramps or at aisle ramps serving seating in assembly areas....
-
11B-1008.2.5.3 Handrails
Where required on ramps serving play components, the handrails shall comply with Section 11B-505 except as modified by Section 11B-1008.2.5.3. Exceptions: 1. ...
-
11B-1008.2.5.3 Handrails
Where required on ramps serving play components, the handrails shall comply with Section 11B-505 except as modified by Section 11B-1008.2.5.3. Exceptions: 1....
- AJW Architectural Products UG2-Railing UG2X-Y108 108" Concealed Snap Flange, 1.25" Diameter, Peened Grip - Configuration Y
- AJW Architectural Products UG30-Railing UG30X-Y108 108" Concealed Set Screw Flange, 1.5" Diameter, Peened Grip - Configuration Y
- AJW Architectural Products UG20-Railing UG20X-Y108 108" Concealed Set Screw Flange, 1.25" Diameter, Peened Grip - Configuration Y
-
Can handrails be mounted to guard rails?
Yes, handrails can be installed on guard rails if all applicable requirements are met....
-
505.1 General
Handrails are required on ramp runs with a rise greater than 6 inches (150 mm) (see 405.8) and on certain stairways (see 504)....
-
505.1 General
Handrails are required on ramp runs with a rise greater than 6 inches (150 mm) (see 405.8) and on certain stairways (see 504)....
-
505.1 General
Handrails are required on ramp runs with a rise greater than 6 inches (150 mm) (see 405.8) and on certain stairways (see 504)....
-
Handrails: ADA Standard Section 405.8
Section 405.8 covers the current ADA Standards for ramp handrails.
-
11B-505.1 General
Handrails are required on ramp runs with a rise greater than 6 inches (150 mm) (see 405.8) and on certain stairways (see 504)....
-
11B-505.1 General
Handrails are required on ramp runs with a rise greater than 6 inches (150 mm) (see 405.8) and on certain stairways (see 504)....
-
11B-505.1 General
Handrails provided along walking surfaces complying with Section 11B-403, required at ramps complying with Section 11B-405, and required at stairs complying with Section 11B-504 shall comply...
-
Circular Cross Section and Clearance (§505.5, §505.7)
Circular Cross Section and Clearance (§505.5, §505.7)...
-
Sections 505.10.2 and 505.10.3
Sections 505.10.2 and 505.10.3 of the 2010 Standards require handrail extensions at both the top and bottom of a flight of stairs....
-
11B-306.3.4 Clearance reduction
Between 9 inches (229 mm) and 27 inches (686 mm) above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches...
-
4.9.4(2)
(2) If handrails are not continuous, they shall extend at least 12 in (305 mm) beyond the top riser and at least 12 in (305 mm) plus the width of one tread beyond the bottom riser....
-
Stairs
Error/Omission: Handrail extensions are not provided at the top and bottom risers....
-
Can handrails or other elements overlap door maneuvering clearances?
No, door maneuvering clearances must be free of any overlapping objects, even those providing knee and toe clearance, which can interfere with maneuvering at doors and doorways....
-
Section 4.9.4
• Section 4.9.4 of the 1991 Standards requires handrails at the bottom of stairs to continue to slope for a distance of the width of one tread beyond the bottom riser nosing and to further...
-
Handrails, Grab Bars, and Tub and Shower Seats [4.26]
Handrails, Grab Bars, and Tub and Shower Seats [4.26] ADAAG 4.26 provides technical requirements for: handrails at ramps [4.8] and stairs [4.9] grab bars at water closets...
-
R409.10.1 Top and Bottom Extension at Ramps
Ramp handrails shall extend horizontally above the landing for 305 mm (1.0 ft) minimum beyond the top and bottom of ramp runs....