The maximum force for pushing or pulling open a door shall be as follows: (1) Fire doors shall have the minimum opening force allowable by the appropriate administrative authority....
Search Results "Door Swing"
-
4.13.11* DOOR OPENING FORCE
- Cal-Royal Products Swing Clear Hinges
-
A4.13.11 Door Opening Force
Although some people cannot manage the allowable forces in this guideline and many others have difficulty, door closers must have certain minimum closing forces to close doors satisfactorily...
-
A4.13.11 DOOR OPENING FORCE
Although some people cannot manage the allowable force in this standard and many others have difficulty, door closers must have certain minimum closing forces to close doors satisfactorily...
- Gamco Swing Up Grab Bar - 125-Swing-Up
-
11B-604.8.2.2 Doors
Toilet compartment doors, including door hardware, shall comply with Section 11B-404, except that if the approach is to the latch side of the compartment door, clearance between the door...
-
11B-604.8.1.2 Doors
Doors shall not swing into the clear floor space or clearance required for any fixture....
-
11B-604.8.1.2 Doors
Doors shall not swing into the clear floor space or clearance required for any fixture....
-
404.2.4.2 Doorways without Doors or Gates
404.2.4.2 Doorways without Doors or Gates, Sliding Doors, and Folding Doors....
-
404.2.4.2 Doorways without Doors or Gates
Sliding Doors, and Folding Doors....
-
Can doors swing into required clear floor or ground space?
Doors cannot swing into required clear floor or ground spaces in these specific instances: clear floor space at controls for automatic and power assisted doors and gates (404.3.5...
-
Doors
DOORS 32” clear width 11B-404.2.3 Maneuvering clearances 11B-404.2.4.1 Level...
-
Doors
DOORS 32” clear width 11B-404.2.3 Maneuvering clearances 11B-404.2.4.1 Level...
-
11B-409.3.1 Power operation
Elevator car and hoistway doors and gates shall be power operated and shall comply with ANSI/BHMA A156.19....
-
11B-409.3.1 Power operation
Elevator car and hoistway doors and gates shall be power operated and shall comply with ANSI/BHMA A156.19....
-
404.2.9 Door and Gate Opening Force
404.2.9 Door and Gate Opening Force. Fire doors shall have a minimum opening force allowable by the appropriate administrative authority....
-
11B-206.5.3 Transient lodging facilities
In transient lodging facilities, entrances, doors, and doorways providing user passage into and within guest rooms that are not required to provide mobility features complying with Section...
-
11B-206.5.3 Transient lodging facilities
In transient lodging facilities, entrances, doors, and doorways providing user passage into and within guest rooms that are not required to provide mobility features complying with Section...
-
A4.17.5 Doors
To make it easier for wheelchair users to close toilet stall doors, doors can be provided with closers, spring hinges, or a pull bar mounted on the inside surface of the door near the hinge...
-
A4.17.5 DOORS
To make it easier for wheelchair users to close toilet stall doors, doors can be provided with closers, spring hinges, or a pull bar mounted on the inside surface of the door near the hinge...
-
C. Doors
Doors - Examine each of the interior routes described above: ...with the exception of doors at shallow closets, do the doors to required accessible spaces, and all doors into and within...
-
404.2.6 Doors in Series and Gates in Series
The distance between two hinged or pivoted doors in series and gates in series shall be 48 inches (1220 mm) minimum plus the width of doors or gates swinging into the space....
-
404.2.6 Doors in Series and Gates in Series
404.2.6 Doors in Series and Gates in Series....
-
404.2.6 Doors in Series and Gates in Series
The distance between two hinged or pivoted doors in series and gates in series shall be 48 inches (1220 mm) minimum plus the width of doors or gates swinging into the space....