Elements located in corners can be difficult to reach from a side approach. Recommendation: Where a side reach is provided, locate elements away from corners in...
Search Results "Compartment Depth"
Commonly Searched Documents
-
Side Reach Radius
-
11B-308.3 Side reach.
[See subsections ...]
-
11B-308.3 Side reach
[See subsections ...]
-
Shower Compartments
Shower Compartments....
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
In a wheelchair accessible compartment with a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide...
-
11B-604 WATER CLOSETS AND TOILET COMPARTMENTS
[See subsections ...]
-
11B-604 Water closets and toilet compartments
[See subsections ...]
-
308.3.1 Unobstructed
An obstruction shall be permitted between the clear floor or ground space and the element where the depth of the obstruction is 10 inches (255 mm) maximum. 2....
-
H17
H17. Is at least 9 inches of toe clearance provided under the front wall and at least one side wall of the toilet stall? [ADA Standards § 4.17.4] Yes No
-
11B-604.9 Water closets and toilet compartments for children's use
SECTION TITLE NOTES 11B-604.9 Water closets and toilet compartments for children's use....
-
604.6 Flush Controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with 604.8.2....
-
11B-604.6 Flush controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with Section 11B-604.8.2....
-
11B-604.6 Flush controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with Section 11B-604.8.2....
-
11B-604.6 Flush controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with Section 11B-604.8.2....
-
d. ii.
d. ii. Provide handles, locks and other operating devices that have a shape that is easy to grasp with one hand and does not require tight grasping and twisting actions of the wrist...
-
Baby Changing Tables
Commenters noted that baby changing tables should not be permitted in accessible compartments since they can interfere with access....
-
11B-608.9 Shower floor or ground surface
Floor or ground surfaces of showers shall comply with Section 11B-302.1 and shall be sloped 1:48 maximum in any direction. Where drains are provided, grate openings shall be ¼ inch...
-
11B-504.2 Treads and risers
All steps on a flight of stairs shall have uniform riser heights and uniform tread depths. Risers shall be 4 inches (102 mm) high minimum and 7 inches (178 mm) high maximum....
-
11B-504.2 Treads and risers
All steps on a flight of stairs shall have uniform riser heights and uniform tread depths. Risers shall be 4 inches (102 mm) high minimum and 7 inches (178 mm) high maximum....
-
11B-504.2 Treads and risers
All steps on a flight of stairs shall have uniform riser heights and uniform tread depths. Risers shall be 4 inches (102 mm) high minimum and 7 inches (178 mm) high maximum....
-
604.8.2.3 Grab Bars
A side-wall grab bar complying with 604.5.1 shall be provided on both sides of the compartment. Figure 604.8.2 Ambulatory Accessible Toilet Compartment...
-
§ 38.127(a)
(a) Sleeping compartments required to be accessible shall be designed so as to allow a person using a wheelchair or mobility aid to enter, maneuver within and approach and use each element...
-
11B-604.8.2.3 Grab bars
A side-wall grab bar complying with Section 11B-604.5.1 shall be provided on both sides of the compartment. FIGURE 11B-604.8.2 ‡‡ AMBULATORY ACCESSIBLE TOILET COMPARTMENT...
-
604.6 Flush Controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with 604.8.2. Advisory 604.6 Flush Controls....