Curb ramps and blended transitions shall comply with Section 11B-406.5.
Search Results "Common Errors"
-
11B-406.5 Common requirements
-
Common Problems with Routes to Building Entrances
Common Problems with Routes to Building Entrances Ø The route has steps but no ramp....
-
Error/Omission: Landing areas where ramps change direction (e.g., switchbacks or 90° turns) are too small.
Error/Omission: Landing areas where ramps change direction (e.g., switchbacks or 90° turns) are too small....
-
Error/Omission: Adequate maneuvering clearance is not provided at doors, including doors to accessible toilet stalls.
Error/Omission: Adequate maneuvering clearance is not provided at doors, including doors to accessible toilet stalls....
-
Error/Omission: The shape of the door hardware requires tight grasping, pinching, and twisting of the wrist to use.
Doors Error/Omission: The shape of the door hardware requires tight grasping, pinching, and twisting of the wrist to use....
-
Error/Omission: Food service queuing areas are too narrow and do not provide adequate clear width for turns.
Error/Omission: Food service queuing areas are too narrow and do not provide adequate clear width for turns....
-
§100.205(c)
(c) All covered multifamily dwellings for first occupancy after March 13, 1991 with a building entrance on an accessible route shall be designed and constructed in such a manner that—
-
1. Common Problems and Solutions in Website Accessibility
Let’s look at several common problems and solutions. This is a small sample of relatively basic problems with web design....
-
Error/Omission: Doors into and within guest rooms that are not accessible guest rooms do not provide at least 32" clear opening width.
Error/Omission: Doors into and within guest rooms that are not accessible guest rooms do not provide at least 32" clear opening width....
-
Error/Omission: When a transfer shower is used, it is often larger than the required 36" x 36" size.
Error/Omission: When a transfer shower is used, it is often larger than the required 36" x 36" size....
-
Guidelines for Requirement 2
The Guidelines for Requirement 2 present design standards that will make public and common use areas readily accessible to and usable by handicapped persons, as required by §100.205(c)(1...
-
F245.4.2.1 Routes to Common Use and Public Use Areas
At least one outdoor recreation access route shall connect each picnic unit with mobility features with common use and public use areas serving that unit....
-
Common Questions (Clear Floor or Ground Space and Turning Space)
Common Questions...
-
Error/Omission: Toilet rooms with 6 or more toilet stalls lack a 36" wide "ambulatory" toilet stall.
Error/Omission: Toilet rooms with 6 or more toilet stalls lack a 36" wide "ambulatory" toilet stall....
-
Error/Omission: The door to the toilet room swings into the required clear floor space at accessible fixtures, controls, and dispensers.
Error/Omission: The door to the toilet room swings into the required clear floor space at accessible fixtures, controls, and dispensers....
-
Common Problems with Access to Programs, Generally
Common Problems with Access to Programs, Generally Ø Perhaps the most common form of discrimination faced by people with disabilities is when others assume that they will not be...
-
Error/Omission: Parts of an accessible route with slopes that exceed 1:20 lack required features including handrails and edge protection.
Error/Omission: Parts of an accessible route with slopes that exceed 1:20 lack required features including handrails and edge protection....
-
F245.4.2.2 Routes Within Common Use and Public Use Areas
At least one outdoor recreation access route shall connect accessible elements, spaces, and facilities provided within common use and public use areas serving picnic units with mobility...
-
11B-233.3.1.2.6.1 Single building with one common (lobby) entrance
The following may only be used for determining required access to multifamily dwelling units, in a single building with one common (lobby) entrance, located on a site with difficult terrain...
- Access Board: Design Solutions for Common Protruding Objects
-
§100.304(b)(5) A leased property under common private ownership
(5) A leased property under common private ownership;...
-
Common Requirements (R304.5) (Section-by-Section Analysis)
Common Requirements (R304.5) (Section-by-Section Analysis) The clear width of curb ramp runs (excluding flared sides), blended transitions, and turning spaces must be 1.2 meters (4 feet...
-
Common Technical Requirements
The technical requirements for outdoor constructed features apply only to those outdoor constructed features that are required to comply with the technical requirements by the...
-
F244.3 Outdoor Constructed Features in Common Use and Public Use Areas
Where provided in common use and public use areas that serve camping units with mobility features, at least 20 percent, but not less than one, of each type of outdoor constructed feature...