(2) Sliding or folding doors: Force applied parallel to the door at the door pull or latch....
Search Results "Automatic Door"
Commonly Searched Documents
-
A4.13.11(2) Sliding or folding doors
-
A4.13.11(2) Sliding or folding doors
(2) Sliding or folding doors: Force applied parallel to the door at the door pull or latch....
-
Contact: ADA Standard Section 407.3.3.2
Section 407.3.3.2 covers the current ADA Standards for the contact requirements of an elevators reopening device.
-
11B-407.3.3.2 Contact
The device shall not require physical contact to be activated, although contact is permitted to occur before the door reverses....
-
11B-404.2.4.1 Swinging doors and gates
Swinging doors and gates shall have maneuvering clearances complying with Table 11B-404.2.4.1....
-
Entry Doors
Entry Doors Under the ADA Standards for Accessible Design, an accessible doorway must have a minimum clear opening width of 32 inches when the door is opened to 90 degrees....
-
11B-206.5.1 Entrances
Each entrance to a building or facility required to comply with 206.4 shall have at least one door, doorway, or gate complying with 404....
- Hager Companies 4.75" Vestibule Actuator 2-659-0242
-
Doors
Doors: a. Main Lobby restroom: provide a restroom vestibule door with at least 18" of maneuvering clearance on the latch side of the door. See Standards § 4.13.6....
-
4.13.10* Door Closers
If a door has a closer, then the sweep period of the closer shall be adjusted so that from an open position of 70 degrees, the door will take at least 3 seconds to move to a point 3 in (...
-
4.13.10* DOOR CLOSERS
If a door has a closer, then the sweep period of the closer shall be adjusted so that from an open position of 70 degrees, the door will take at least 3 seconds to move to a point 3 in (...
- DORMA ED400 Swing Door Operator
- BEA Inc. PBDGP Series Vestibule Push Plate (Push to Open)
-
11B-404.2.9 Door and gate opening force
The force for pushing or pulling open a door or gate other than fire doors shall be as follows: 1. Interior hinged doors and gates: 5 pounds (22.2 N) maximum. 2. ...
-
11B-404.2.9 Door and gate opening force
The force for pushing or pulling open a door or gate other than fire doors shall be as follows: 1. Interior hinged doors and gates: 5 pounds (22.2 N) maximum. 2....
-
11B-404.2.9 Door and gate opening force
The force for pushing or pulling open a door or gate other than fire doors shall be as follows: Interior hinged doors and gates: 5 pounds (22.2 N) maximum....
-
11B-404.2.9 Door and gate opening force
SECTION TITLE NOTES 11B-404.2.9 Door and gate opening force....
-
11B-404.2.4.1 Swinging doors and gates
Swinging doors and gates shall have maneuvering clearances complying with Table 11B-404.2.4.1....
-
11B-404.2.4.1 Swinging doors and gates
Swinging doors and gates shall have maneuvering clearances complying with Table 11B-404.2.4.1....
- Horton ProSlide® Series 2003 Belt Drive System
-
1132A.3 Width and height of interior doors and secondary exterior doors
Doors shall comply with the following: Doors shall not be less than 6 feet 8 inches (2032 mm) in height. ...
-
5.1.9 Doors
Where provided, doors shall comply with ABAAS section 404. The door shall not swing into or otherwise obstruct the clear floor or ground space or the turning space required by 5.1.4....
- Besam Hurricane Resistant Automatic Sliding Door 1012494 SL500 SA Clean Room BP Narrow Stile Rev 2.0
- Besam Hurricane Resistant Automatic Sliding Door 1012493 SL500 SA Clean Room SS Narrow Stile Rev 2.0