Where the turning space has one entrance/exit point other than the sloped ramp segments, detectable warnings shall be 36 inches (914 mm) deep, as measured perpendicular to the curb, and...
Search Results "Wheelchair Space (Transportation)"
Commonly Searched Documents
-
11B-705.1.2.2.2.1 One entrance/exit point
-
11B-404.3.5 Controls
The clear floor space adjacent to the control shall be located beyond the arc of the door swing. Advisory 11B-404.3.5 Controls. ...
-
7.4.5.2 Slope
The cross slope of a passing space shall not exceed 1:20 (5 percent) in any direction....
-
General: ADA Standard Section 205.1
Section 205.1 of the ADA Standards covers information on scoping requirements for operable parts in the most current ADA Standards.
-
Are detectable warnings required on curb ramps or at hazardous vehicular areas?
Specifically, the curb ramp requirements apply only to public transportation facilities covered by DOT’s ADA Standards....
-
208.2.3 Residential Facilities, F208.2.3 Residential Facilities
Parking spaces provided to serve facilities with residential dwelling units shall comply with 208.2.3....
-
Judicial Spaces: ADA Standard Section 206.7.4
Section 206.7.4 covers scoping requirements in the most current ADA Standards for accessible routes to judicial spaces.
-
Position: ADA Standard Section 703.3.2
Braille shall be positioned below the corresponding text. If text is multi-lined, braille shall be placed below the entire text. Braille shall be separated 3/8 inch (9.5 mm) minimum...
-
11B-603.2 Clearances
Clearances shall comply with Section 11B-603.2.
-
Section 36.308 Seating in Assembly Areas (Preamble, Section-by-Section Analysis)
Many persons in wheelchairs are able to transfer to existing seating with this relatively minor modification....
-
Section 36.308 Seating in Assembly Areas (Section-By-Section Analysis and Response to Comments)
Many persons in wheelchairs are able to transfer to existing seating with this relatively minor modification....
-
Equivalent Facilitation
The Department of Transportation's ADA regulations establish a procedure through which an agency or manufacturer may apply for a determination of equivalent facilitation for alternative...
-
11B-308.2.2 Obstructed high reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....
-
11B-308.2.2 Obstructed high reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....
-
606.2 Clear Floor Space (Exception 3)
606.2 Clear Floor Space (Exception 3) This section requires clear floor space positioned for a forward approach and knee and toe clearance to be provided at lavatories and sinks....
-
Camp Shelters
One full, unobstructed side of the clear ground space must adjoin or overlap the trail or outdoor recreation access route (as applicable) or another clear ground space....
-
3.3.3 Clear Floor Width
The authors argued that individuals can bring their arms and legs inboard when entering transportation vehicles and passing through doorways....
-
306.2.3 Minimum Required Depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (430 mm) minimum under the element....
-
306.2.3 Minimum Required Depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (430 mm) minimum under the element....
-
306.2.3 Minimum Required Depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (430 mm) minimum under the element....
-
11B-305.7.2 Parallel approach
Alcoves shall be 60 inches (1524 mm) wide minimum where the depth exceeds 15 inches (381 mm). FIGURE 11B-305.7.2 MANEUVERING CLEARANCE IN AN ALCOVE, PARALLEL APPROACH
-
305.7.2 Parallel Approach
Alcoves shall be 60 inches (1525 mm) wide minimum where the depth exceeds 15 inches (380 mm). Figure 305.7.2 Maneuvering Clearance in an Alcove, Parallel Approach
-
305.7.1 Forward Approach
Alcoves shall be 36 inches (915 mm) wide minimum where the depth exceeds 24 inches (610 mm). Figure 305.7.1 Maneuvering Clearance in an Alcove, Forward Approach
-
305.7.1 Forward Approach
305.7.1 Forward Approach. Alcoves shall be 36 inches (915 mm) wide minimum where the depth exceeds 24 inches (610 mm). Figure 305.7.1 Maneuvering Clearance in an Alcove,...