Section 308.2.2 covers the current ADA Standards for obstructed high reach.
Search Results "Water Closet Clear Floor Space"
-
Obstructed High Reach: ADA Standard Section 308.2.2
-
Can accessible spaces be parallel instead of perpendicular?
The Standards do not specifically require that accessible spaces be perpendicular instead of parallel, but perpendicular parking spaces are preferred at facilities located on sites because...
- American Standard AccessPRO Toilet
-
PEMKO 3" Floor Plates/Safety Treads No. 191
Requires the Premium User plan or above. (Login or upgrade your account!)
-
11B-805.2.4 Toilet and bathing rooms
Where provided, one water closet, one lavatory, and one bathtub or shower shall comply with the applicable requirements of Sections 11B-603 through 11B-610....
-
11B-805.2.4 Toilet and bathing rooms
Where provided, one water closet, one lavatory, and one bathtub or shower shall comply with the applicable requirements of Sections 11B-603 through 11B-610....
-
11B-405.4 Floor or ground surfaces
Floor or ground surfaces of ramp runs shall comply with Section 11B-302. Changes in level other than the running slope and cross slope are not permitted on ramp runs....
-
7(2)(b)(vi)
(vi) Bathtubs and tub/showers located in the bathroom provide a clear access aisle adjacent to the lavatory that is at least 2'6" wide and extends for a length of 4'0" (measured from the...
-
1011.2.3 Slope
The slope of the clear ground space surface shall not be steeper than 1:48 in any direction....
-
11B-217.4.2 Floor requirement
TTYs in public buildings shall be provided in accordance with Section 11B-217.4.2.1. TTYs in private buildings shall be provided in accordance with Section 11B-217.4.2.2.
-
Benches [1011.2]
A minimum of 36 by 48 inches of clear ground space must be provided near a bench, with one side of the clear space adjoining an ORAR or trail as applicable....
-
304 Turning Space
-
Can accessible routes run behind other parking spaces?
The ADA Standards require that an accessible route connect parking space access aisles to the accessible entrance they serve but they do not specifically prohibit the accessible route from...
- San Jamar C4150SS Small Pull-Type Water Cup Dispenser
- San Jamar C4160WH Small Pull-Type Water Cup Dispenser
-
16.1 Q. Will a standard hung 32-inch door provide sufficient clear width to meet the requirements of the Fair Housing Act?
No, a 32-inch door would not provide a sufficient clear opening to meet the requirement for usable doors....
-
11B-226.1 General
Where dining surfaces are provided for the consumption of food or drink, at least 5 percent of the seating spaces and standing spaces at the dining surfaces shall comply with Section 11B...
-
11B-217.4.2 Floor requirement
TTYs in public buildings shall be provided in accordance with Section 11B-217.4.2.1. TTYs in private buildings shall be provided in accordance with Section 11B-217.4.2.2.
-
Perpendicular and Angled Parking Spaces (R309.3) (Section-by-Section Analysis)
Perpendicular and Angled Parking Spaces (R309.3) (Section-by-Section Analysis) An access aisle must be provided at street level for the entire length of each accessible perpendicular...
-
3. Toilet Centerline
3. Is the accessible toilet in each accessible guestroom bathroom centered 18" from the adjacent side wall, which is the distance that will permit a person with a mobility impairment...
-
11B-1002.5.4 Wheelchair storage space
Wheelchair storage spaces complying with Section 11B-305 shall be provided in or adjacent to unload areas for each required amusement ride seat designed for transfer and shall not overlap...
- Wikk Industries Inc. PART# BPS SM-ING48 DB (710) with I36-3 Clear (628)
-
Exceptions Considered for Wheelchair Spaces on Raised Platforms
The exception to the minimum depth in M303.2.3 for wheelchair spaces entered from the front or rear would permit a portion of the 48 inch minimum depth of the wheelchair space that accommodates...
-
11B-1002.6.3 Wheelchair storage space
Wheelchair storage spaces complying with Section 11B-305 shall be provided in or adjacent to unload areas for each required transfer device and shall not overlap any required means of egress...