employee lot according to the general scoping requirement in Table 11B-208.2....
Search Results "Supplemental Requirement"
Commonly Searched Documents
-
11B-208.2.1 Hospital outpatient facilities
-
11B-208.2.1 Hospital outpatient facilities
employee lot according to the general scoping requirement in Table 11B-208.2....
-
Check-Out Aisles and Sales and Service Counters
The nondiscrimination requirements of the ADA regulations require the level of service provided at the accessible portion of any sales and service counter to be the same as the level of...
-
F203.10 Raised Refereeing, Judging, and Scoring Areas
Raised structures used solely for refereeing, judging, or scoring a sport shall not be required to comply with these requirements or to be on an accessible route....
-
203.10 Raised Refereeing, Judging, and Scoring Areas
Raised structures used solely for refereeing, judging, or scoring a sport shall not be required to comply with these requirements or to be on an accessible route....
-
Is there a maximum distance between ramp handrails?
No, only a minimum (36”) is required between handrails. The Standards do not require center or intermediate handrails on wide ramps....
- Stanley QCL 200 Series Grade 2 Standard Duty Cylindrical Locks
- Playworld® SMARTE Safety Surfacing
- TownSteel ED6500 Narrow Stile Panic Rim Device
- LS-80 Basic Stationary IR System
- Sargent 421 Cam Action Door Closer
- Bobrick Koala Kare Horizontal, Wall Mounted With Stainless Steel Veneer Baby Changing Station KB200-SS
- Advent Sebring Wall Sconce with Emergency Battery Back-Up
- Inpro Corporation ENDURANT® Trench Drain Receptor
- Detectable Warning Systems, Inc. AlertTile® Detectable Warning
-
810.6.2 Routes and Destinations
Signs covered by this requirement shall, to the maximum extent practicable, be placed in uniform locations within the system....
-
229 Windows
229 Windows A new requirement at section 229.1 of the 2010 Standards provides that if operable windows are provided for building users, then at least one window in an accessible space...
-
11B-206.4.4.3 Key stations and intercity rail stations
Key stations and existing intercity rail stations required by Subpart C of 49 CFR part 37 to be altered, shall have entrances complying with Section 11B-404....
-
806.2.4 Toilet and Bathing Facilities
No fewer than one water closet, one lavatory, and one bathtub or shower shall comply with applicable requirements of 603 through 610....
-
Thresholds at Doorways
The 1991 Standards, at section 4.13.8, require the height of thresholds at doorways not to exceed ½ inch and thresholds at exterior sliding doors not to exceed ¾ inch....
-
Lines of Sight at Dining Areas in Sports Venues
Under this exception, access is not required to all dining areas, as is otherwise required....
-
B. M301 Diagnostic Equipment Used by Patients in a Supine, Prone, or Side-lying Position and M302 Diagnostic Equipment Used by Patients in a Seated Position
In the final rule M301 and M302 provide the technical requirements for diagnostic equipment used in the supine, prone, or side-lying position, and diagnostic equipment used by patients in...
-
1007.2.1 Buildings with four or more stories
In buildings where a required accessible floor is four or more stories above or below a level of exit discharge, at least one required accessible means of egress shall be an elevator complying...
-
405.9 Edge Protection
Edge protection shall not be required on ramps that are not required to have handrails and have sides complying with 406.3. 2....