compliant - no hand operation Sensing field preset at 27.5" max. but adjustable by remote programmer 44-931 (sold separately) Infrared sensor replaceable User friendly 3 seconds flush delay...
Search Results "Door Delay"
- Gerber Electronic Toilet Flush Valve 44-912
-
11B-806.3.2 Notification devices
Visible notification devices shall be provided to alert room occupants of incoming telephone calls and a door knock or bell....
-
11B-806.3.2 Notification devices
Visible notification devices shall be provided to alert room occupants of incoming telephone calls and a door knock or bell....
-
Attachment G: Modifications to Newly Constructed Facilities
Attachment G: Modifications to Newly Constructed Facilities
-
4. Pressure Gauge
Many people with disabilities have limitations on the amount of force they can exert to open a door or operate a device that requires pushing or pulling....
-
1133B.2.5.2
SECTION 1133B GENERAL ACCESSIBILITY FOR ENTRANCES, EXITS AND PATHS OF TRAVEL 1133B.2 Doors. 1133B.2.5.2 Hand-activated door opening hardware, handles, pulls, latches, locks and...
-
III-4.4300 Standards to apply
However, because of space constraints, he is unable to widen the door to the full 32-inch clearance required for alterations under ADAAG....
-
1013.4 Raised character and braille exit signs
Each grade-level exterior exit door that is required to comply with Section 1013.1 shall be identified by a tactile exit sign with the word, “EXIT.” 2....
-
O. Accessible Portable Toilets
For the entrance to an accessible portable toilet to be usable, there must either be no step or a ramp must be installed that extends extends from the hinge side of the door to at least...
-
11B-213.2.1 Unisex (single-user or family) toilet and unisex (single-user or family) bathing rooms
Doors to unisex (single-user or family) toilet rooms and unisex bathing rooms shall have privacy latches....
-
11B-216.8.3 Signs at toilet and urinal compartments
Exception: A sign with tactile characters shall be permitted on an in-swinging and self-closing door at compartments not required to comply with Section 11B-604 or Section 11B-605.5....
-
11B-216.8.3 Signs at toilet and urinal compartments
Exception: A sign with tactile characters shall be permitted on an in-swinging and self-closing door at compartments not required to comply with Section 11B-604 or Section 11B-605.5....
-
11B-213.2.1 Unisex (single-user or family) toilet and unisex (single-user or family) bathing rooms
Doors to unisex (single-user or family) toilet rooms and unisex bathing rooms shall have privacy latches....
-
Single-User Toilet Rooms: Split Plumbing
Note that lavatories (and other fixtures) cannot overlap door maneuvering clearances, including latch-side clearances....
-
Signage
If Braille and raised letter signs are mounted on doors instead of walls, blind persons and persons with low vision may be hurt by someone who is pushing a door open while they are trying...
-
A4.34.6.7 OVENS
Countertop or wall-mounted ovens with side-opening doors are easier for people in wheelchairs to use....
- Boost Your Business - Chapter 9 - Restroom Clear Space
- Door King Inc. 1837 PC Programmable Telephone Entry and Access Control System
- Jacknob Corp. 9099 ADA Latch & Keeper Surface-Mounted Partition Door Hardware
-
Kitchen Appliances
In the addition, the Board has added exceptions for appliance doors and door latching devices in section 804.6.2. Comment....
- Sensible Innovations AWARE App
-
Minimum Clear Headroom
The commenters stated that standard doors provide a height range from 75 to 79 inches, and that an 80-inch specification would considerably increase the cost of each door installed....
-
4.13.11(2)
(2) Other doors....