) and 4 electrified options Uses standard mortise prep MicroShield® antimicrobial finish option Matching behavioral health thumbturn available UL Listed for use with Fire Rated doors...
Search Results "Compartment Door"
- Sargent 8200 Mortise Lock with BHL Trim
-
11B-608.5.2 Standard roll-in type shower compartments
In standard roll-in type shower compartments, the controls, faucets, and the shower spray unit shall be located on the back wall of the compartment adjacent to the seat 16 inches (406 mm...
- Corbin Russwin Inc. ED7000 Series Narrow Stile Crossbar Exit Device
-
11B-608.3.2 Standard roll-in type shower compartments
[2010 ADAS] 608.3.2 Standard Roll-In Type Shower Compartments....
-
11B-408.4.1 Car dimensions and doors
Car doors shall be positioned at the narrow ends of cars and shall provide 32 inches (813 mm) minimum clear width....
-
11B-408.4.1 Car dimensions and doors
Car doors shall be positioned at the narrow ends of cars and shall provide 32 inches (813 mm) minimum clear width....
-
11B-608.5.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, operable parts of controls and faucets shall be installed on the side wall of the compartment adjacent to the seat wall 19 inches (483 mm)...
-
11B-608.5.3 Alternate roll-in type shower compartments
11B-608.5.3 Alternate roll-in type shower compartments....
-
11B-608.5.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located on the side wall of the compartment adjacent to the 16 inches (406 mm) minimum...
- Yale 7000 Series Exit Devices
-
Guidelines for Requirement 2
The Guidelines for Requirement 2 present design standards that will make public and common use areas readily accessible to and usable by handicapped persons, as required by...
-
608.3.2 Standard Roll-In Type Shower Compartments
Where a seat is provided in standard roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall opposite the seat....
-
608.5.1 Transfer Type Shower Compartments
In transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1220 mm...
- BEA Inc. Keyswitches Access Control Devices
-
11B-608.3.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
- Architectural Builders Hardware Mfg., Inc. 6000 Series Push/Pull Hospital Latch
- SafePath EntryLevelâ„¢ Landings
-
11B-608.5.2 Standard roll-in type shower compartments
In standard roll-in type shower compartments, operable parts of controls and faucets shall be installed on the back wall of the compartment adjacent to the seat wall 19 inches (483 mm) minimum...
-
11B-608.5.2 Standard roll-in type shower compartments
11B-608.5.2 Standard roll-in type shower compartments....
-
Lavatory and Accessory Layout by Terry Salo, Architect, CASp
Lavatory and Accessory Layout by Terry Salo, Architect, CASp NOTE: The trash receptacle is preferred to be near the door to allow people to pull the door open with a paper towel...
-
608.5.2 Standard Roll-In Type Shower Compartments
In standard roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the shower floor...
-
608.5.3 Alternate Roll-In Type Shower Compartments
In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the shower floor...
- TownSteel ED6700 Narrow Stile Concealed Vertical Panic Device
-
11B-608.2.3 Alternate roll-in type shower compartments
Alternate roll-in type shower compartments shall be 36 inches (914 mm) wide and 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides....