At ground level, the clear width of accessible routes shall be 60 inches (1525 mm) minimum. EXCEPTIONS: 1....
Search Results "Accessible Space"
-
1008.2.4.1 Ground Level
-
11B-1008.2.4.1 Ground level
At ground level, the clear width of accessible routes shall be 60 inches (1524 mm) minimum. Exceptions: 1. ...
-
11B-1008.2.4.1 Ground level
At ground level, the clear width of accessible routes shall be 60 inches (1524 mm) minimum. Exceptions: 1....
-
11B-1008.2.4.1 Ground level
At ground level, the clear width of accessible routes shall be 60 inches (1524 mm) minimum....
-
6.3
6.3 Wheelchair spaces shall be integrated into their seat row and shall not be separated by any aisle or other break from the companion seat in the same row....
-
No accessible meeting sites
□ At locations where absolutely no accessible meeting sites are available (such as some remote sites), take every action to ensure people with disabilities have an equal opportunity to participate...
-
1003.2.13.4 Platform lifts
Platform (wheelchair) lifts shall not serve as part of an accessible means of egress, except where allowed as part of a required accessible route in Section 1108.7....
-
Clear Deck Space
Clear Deck Space Clear deck space must be provided to enable a person to get close enough to the pool lift seat to easily transfer from a wheelchair or mobility device....
-
§ 35.138(b) Identification of available accessible seating
(b) Identification of available accessible seating. A public entity that sells or distributes tickets for a single event or series of events shall, upon inquiry—...
-
3.2.6 Identification of Accessible Camping Units
Accessible camping units shall be identified at an entrance kiosk, on a bulletin board, or on a sign at the registration area of a campground....
-
11B-308.2.2 Obstructed high reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....
-
11B-308.2.2 Obstructed high reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....
-
4.34.2(2)
(2) Accessible spaces shall have maneuvering space complying with 4.2.2 and 4.2.3 and surfaces complying with 4.5....
-
2.9.1 Natural Elements
Accessibility guidelines for protruding objects do not apply to natural elements such as tree branches and rock formations....
-
II. Exterior Routes...
In order for persons with disabilities to use a facility, there must be at least one accessible route that allows persons who use wheelchairs or other mobility aids to approach, enter and...
-
306.2.3 Minimum Required Depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (430 mm) minimum under the element....
-
306.2.3 Minimum Required Depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (430 mm) minimum under the element....
-
306.2.3 Minimum Required Depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (430 mm) minimum under the element....
-
Error/Omission: The built-up curb ramp projects into the access aisle.
Error/Omission: The built-up curb ramp projects into the access aisle. The accessible parking space and access aisle is not level in all directions....
-
Clear Floor and Turning Space Inside Examination Rooms
Clear Floor and Turning Space Inside Examination Rooms In order for accessible equipment to be usable by an individual who uses a wheelchair or other mobility device, that individual...
-
11B-305.7.2 Parallel approach
Alcoves shall be 60 inches (1524 mm) wide minimum where the depth exceeds 15 inches (381 mm). FIGURE 11B-305.7.2 MANEUVERING CLEARANCE IN AN ALCOVE, PARALLEL APPROACH
-
305.7.2 Parallel Approach
Alcoves shall be 60 inches (1525 mm) wide minimum where the depth exceeds 15 inches (380 mm). Figure 305.7.2 Maneuvering Clearance in an Alcove, Parallel Approach
-
305.7.1 Forward Approach
Alcoves shall be 36 inches (915 mm) wide minimum where the depth exceeds 24 inches (610 mm). Figure 305.7.1 Maneuvering Clearance in an Alcove, Forward Approach
-
305.7.1 Forward Approach
305.7.1 Forward Approach. Alcoves shall be 36 inches (915 mm) wide minimum where the depth exceeds 24 inches (610 mm). Figure 305.7.1 Maneuvering Clearance in an Alcove,...