Space under an element between the finish floor or ground and 9 inches (229 mm) above the finish floor or ground shall be considered toe clearance and shall comply with Section 11B-306.2...
Search Results "Ground Level Play Component"
Commonly Searched Documents
-
11B-306.2.1 General
-
306.2.1 General
Space under an element between the finish floor or ground and 9 inches (230 mm) above the finish floor or ground shall be considered toe clearance and shall comply with 306.2....
-
11B-306.2.1 General
Space under an element between the finish floor or ground and 9 inches (229 mm) above the finish floor or ground shall be considered toe clearance and shall comply with Section 11B-306.2...
-
11B-306.2.1 General
Space under an element between the finish floor or ground and 9 inches (229 mm) above the finish floor or ground shall be considered toe clearance and shall comply with Section 11B-306.2...
-
1015.3 Viewing Space
This section requires each distinct viewing location to provide a viewing space adjacent to the clear ground space required by 1015.2 through which the point of interest is viewable....
-
b. Exception for Base Support Allowance and Unobstructed Knee and Toe Space
Allowing a maximum base support height of 1.5 inches will provide room for the structural components necessary for an effective base support design and will also be accessible by around...
-
Mobility
down steep paths, moving over rough or uneven surfaces, using toilet and bathing facilities, reaching and seeing items placed at conventional heights, and negotiating steps or changes in level...
-
[2010 ADAS] 105.2.4 ICC/IBC
The IBC also provides requirements for areas of refuge, which are fire-rated spaces on levels above or below the exit discharge levels where people unable to use stairs can go to register...
-
F105.2.4 ICC/IBC
The IBC also provides requirements for areas of refuge, which are fire-rated spaces on levels above or below the exit discharge levels where people unable to use stairs can go to register...
-
105.2.4 ICC/IBC
The IBC also provides requirements for areas of refuge, which are fire-rated spaces on levels above or below the exit discharge levels where people unable to use stairs can go to register...
-
105.2.4 ICC/IBC
The IBC also provides requirements for areas of refuge, which are fire-rated spaces on levels above or below the exit discharge levels where people unable to use stairs can go to register...
-
ICC/IBC
The IBC also provides requirements for areas of refuge, which are fire-rated spaces on levels above or below the exit discharge levels where people unable to use stairs can go to register...
-
SHOPPING CENTER (OR SHOPPING MALL)
A shopping center may include a series of buildings on a common site, connected by a common pedestrian access route on, above or below the ground floor, that is either under common ownership...
-
5.1 Costs Included
The direct or "hard" costs shall not be reduced by the value of components, assemblies, building equipment or construction not directly associated with accessibility or usability....
-
11B-611.2 Clear Floor Space
A clear floor or ground space complying with Section 11B-305 positioned for parallel approach shall be provided. The clear floor or ground space shall be centered on the appliance....
-
Operable controls (Preamble, Section-by-Section Analysis)
The proposed rule defined operable controls as those components of a product that require physical contact for normal operation of the device....
- S.R. Smith Splash! Pool Lift Video 2: Advanced Troubleshooting
-
1009.2.1 Elevators required
In buildings where a required accessible floor or occupied roof is four or more stories above or below a level of exit discharge, not less than one required accessible means of egress shall...
-
221.2.3.2 Vertical Dispersion
Wheelchair spaces shall be dispersed vertically at varying distances from the screen, performance area, or playing field....
-
Height: ADA Standard Section 1005.2.1
At least 25 percent of the railings, guards, or handrails shall be 34 inches (865 mm) maximum above the ground or deck surface....
-
Submerged Depth: ADA Standard Section 1009.2.8
The lift shall be designed so that the seat will submerge to a water depth of 18 inches (455 mm) minimum below the stationary water level....
-
Illumination: ADA Standard Section 407.4.5
Section 407.4.5 covers the current ADA Standards for the illumination of the elevator car controls, platform, car threshold and car landing sill.
-
11B-407.4.5 Illumination
The level of illumination at the car controls, platform, car threshold and car landing sill shall be 5 foot candles (54 lux) minimum....
-
11B-1009.2.8 Submerged depth
The lift shall be designed so that the seat will submerge to a water depth of 18 inches (457 mm) minimum below the stationary water level....